Mid-term results of modified L-shaped incision technique for supracardiac total anomalous pulmonary venous connection.

Zicong Feng1, Yang Yang1, Fengpu He2, Kunjing Pang1, Kai Ma1, Sen Zhang1, Lei Qi1, Guanxi Wang1, Fengqun Mao1, Jianhui Yuan1, Shoujun Li1.   

Abstract

OBJECTIVES: Surgical outcomes of supracardiac total anomalous pulmonary venous connection (TAPVC) repair by the posterior technique (PT) remain unsatisfactory. This study aimed to compare the outcomes of the modified L-shaped incision technique with the PT for supracardiac TAPVC repair.
METHODS: From January 2009 to December 2019, 121 consecutive patients with supracardiac TAPVC undergoing surgical repair in our institution were included (L-group, n = 53; PT group, n = 68). A propensity score-matched analysis was performed. Patients with single-ventricle physiology or atrial isomerism were excluded. All clinical data were retrospectively analysed.
RESULTS: In the unmatched cohort, the median follow-up duration was 33 months (interquartile range 26-65 months). There were 5 operative mortalities (4.1%) and 12 late mortalities (9.9%). Postoperative pulmonary venous obstruction (PVO) was documented in 21 patients. After matching (52 pairs), the overall survival rate in the L-group was 88.2% at both 3 and 5 years. For the propensity score-matched patients with preoperative PVO (n = 20), statistically significant differences (P = 0.002) were found by Kaplan-Meier curves with freedom from death and postoperative PVO at 1 and 3 years of 100% and 85.7% [standard deviation (SD): 13.2%] in the L-group and 90% (SD: 9.5%) and 22.9% (SD: 14.1%) in the PT group, respectively. Multivariable analysis revealed that the use of the PT was an independent risk factor for death and postoperative PVO (hazard ratio 4.12, 95% confidence interval 1.12-15.16; P = 0.03).
CONCLUSIONS: The modified L-shaped incision technique provided an acceptable outcome for supracardiac TAPVC repair. Compared with PT, the modified L-shaped incision technique was significantly associated with decreased death and postoperative PVO in patients with obstructed supracardiac TAPVC.
© The Author(s) 2020. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

Entities:  

Keywords:  Modified L-shaped incision technique; Recurrent pulmonary venous obstruction; Supracardiac total anomalous pulmonary venous connection

Mesh:

Year:  2020        PMID: 32888293     DOI: 10.1093/ejcts/ezaa264

Source DB:  PubMed          Journal:  Eur J Cardiothorac Surg        ISSN: 1010-7940            Impact factor:   4.191


  1 in total

1.  Surgical Outcomes of Total Anomalous Pulmonary Venous Connection Repair.

Authors:  Radoslaw Jaworski; Andrzej Kansy; Joanna Friedman-Gruszczynska; Katarzyna Bieganowska; Malgorzata Mirkowicz-Malek
Journal:  Medicina (Kaunas)       Date:  2022-05-23       Impact factor: 2.948