Literature DB >> 32887101

Novel microfluidic paper-based analytical devices (μPADs) for the determination of nitrate and nitrite in human saliva.

Francisca T S M Ferreira1, Raquel B R Mesquita2, António O S S Rangel1.   

Abstract

In this work, two different microfluidic paper-based analytical devices (μPADs) were developed for the quantification of nitrite and nitrate in human saliva samples, in order to aid in the diagnosis of some diseases and health conditions associated with these ions. The development of these nitrite and nitrate μPADs involved several studies to optimize their design and construction, including an interference assessment and stability studies. These μPADs allowed a nitrite determination in a range of 5-250 μM with limits of detection and quantification of 0.05 μM and 0.17 μM, respectively, and a nitrate determination in the range 0.2-1.2 mM with limits of detection and quantification of 0.08 mM and 0.27 mM, respectively. As for the stability, both of the μPADs were stable when stored in vacuum at 4 °C (the nitrite μPAD for at least 60 days and the nitrate μPAD for at least of 14 days) and, after the sample placement, the nitrite and nitrate μPADs could be scanned within the first 4 and 2 h, respectively. The nitrite μPAD measurements were compared with the ones obtained from the standard colorimetric method and there were no statistically significant differences between these two methods. To evaluate the accuracy of nitrate μPAD measurements, 4 certified water samples were used and recovery studies using saliva samples were performed.
Copyright © 2020 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Disposable devices; Nitrate reduction; Nitrite determination; Point-of-care; Saliva analysis

Mesh:

Substances:

Year:  2020        PMID: 32887101     DOI: 10.1016/j.talanta.2020.121183

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  5 in total

1.  New microfluidic paper-based analytical device for iron determination in urine samples.

Authors:  Francisca T S M Ferreira; Karina A Catalão; Raquel B R Mesquita; António O S S Rangel
Journal:  Anal Bioanal Chem       Date:  2021-10-15       Impact factor: 4.142

2.  Design and Functionalization of a µPAD for the Enzymatic Determination of Nitrate in Urine.

Authors:  Francisca T S M Ferreira; Raquel B R Mesquita; António O S S Rangel
Journal:  Molecules       Date:  2021-10-21       Impact factor: 4.411

3.  Nitrite enhanced detection from saliva by simple geometrical modifications of paper-based micromixers.

Authors:  Elham Mollaie; Sasan Asiaei; Hiwa Aryan
Journal:  Microfluid Nanofluidics       Date:  2022-10-12       Impact factor: 3.090

Review 4.  Increasing the packing density of assays in paper-based microfluidic devices.

Authors:  Sajjad Rahmani Dabbagh; Elaina Becher; Fariba Ghaderinezhad; Hayati Havlucu; Oguzhan Ozcan; Mehmed Ozkan; Ali Kemal Yetisen; Savas Tasoglu
Journal:  Biomicrofluidics       Date:  2021-02-04       Impact factor: 2.800

Review 5.  Saliva, a bodily fluid with recognized and potential diagnostic applications.

Authors:  Mozhgan Boroumand; Alessandra Olianas; Tiziana Cabras; Barbara Manconi; Daniela Fanni; Gavino Faa; Claudia Desiderio; Irene Messana; Massimo Castagnola
Journal:  J Sep Sci       Date:  2021-08-18       Impact factor: 3.614

  5 in total