Literature DB >> 32868321

Coronary artery spasm following dobutamine stress echocardiogram.

Annick Judenherc Haouzi1, Stefani Schwartz2, Edward Liszka3.   

Abstract

A 53-year-old woman with atypical chest pain underwent a dobutamine stress echocardiogram (DSE) and developed a coronary spasm (CS) with severe pain and dramatic ST-segment elevation 9 min after dobutamine infusion was discontinued. The spasm resolved after sublingual nitroglycerin administration. The same-day coronary angiogram showed non-significant stenosis in the three coronary territories. Retrospectively, we found that the patient had vasospastic angina (VSA), a condition that has been strongly associated with the development of dobutamine-induced CS. Mechanisms of dobutamine-induced CS are not fully understood and include endothelial dysfunction leading to deficient nitric oxide-mediated coronary vasodilation in response to increased myocardial oxygen demand as well as imbalance between β1 and β2 adrenergic effects of dobutamine. Dobutamine-induced CS has also been much more frequently reported in patients from Asian descent with VSA. VSA should be systemically recognised in patients considered for DSE and, if present, other modalities of stress imaging should be discussed. © BMJ Publishing Group Limited 2020. No commercial re-use. See rights and permissions. Published by BMJ.

Entities:  

Keywords:  contraindications and precautions; ischaemic heart disease; prehospital

Mesh:

Substances:

Year:  2020        PMID: 32868321      PMCID: PMC7462237          DOI: 10.1136/bcr-2020-235206

Source DB:  PubMed          Journal:  BMJ Case Rep        ISSN: 1757-790X


  26 in total

Review 1.  Incidence, pathophysiology, and treatment of complications during dobutamine-atropine stress echocardiography.

Authors:  Marcel L Geleijnse; Boudewijn J Krenning; Attila Nemes; Bas M van Dalen; Osama I I Soliman; Folkert J Ten Cate; Arend F L Schinkel; Eric Boersma; Maarten L Simoons
Journal:  Circulation       Date:  2010-04-20       Impact factor: 29.690

2.  A case of dobutamine-induced coronary arterial spasm with ST-segment elevation.

Authors:  H Yamagishi; H Watanabe; I Toda; M Yoshiyama; K Akioka; M Teragaki; K Takeuchi; J Yoshikawa
Journal:  Jpn Circ J       Date:  1998-02

3.  Coronary vasospasm after dobutamine stress echocardiogram triggered by esmolol.

Authors:  Alicia Mateo Martínez; Miryam Martínez Pascual Del Riquelme; Jose María López Ayala; Daniel Saura Espín
Journal:  Int J Cardiol       Date:  2015-05-01       Impact factor: 4.164

4.  Prevalence of coronary artery spasm during dobutamine stress echocardiography.

Authors:  Nicolas Mansencal; Imane El Hajjaji; Rami El Mahmoud; Franck Digne; Olivier Dubourg
Journal:  Am J Cardiol       Date:  2011-12-19       Impact factor: 2.778

5.  Guidelines for Performance, Interpretation, and Application of Stress Echocardiography in Ischemic Heart Disease: From the American Society of Echocardiography.

Authors:  Patricia A Pellikka; Adelaide Arruda-Olson; Farooq A Chaudhry; Ming Hui Chen; Jane E Marshall; Thomas R Porter; Stephen G Sawada
Journal:  J Am Soc Echocardiogr       Date:  2019-11-15       Impact factor: 5.251

6.  Angiographic documented coronary arterial spasm in absence of critical coronary artery stenoses in a patient with variant angina episodes during exercise and dobutamine stress echocardiography.

Authors:  M Roffi; B Meier; Y Allemann
Journal:  Heart       Date:  2000-04       Impact factor: 5.994

7.  Myocardial ischemia due to coronary artery spasm during dobutamine stress echocardiography.

Authors:  H Kawano; H Fujii; T Motoyama; K Kugiyama; H Ogawa; H Yasue
Journal:  Am J Cardiol       Date:  2000-01-01       Impact factor: 2.778

8.  Acute myocardial infarction during a dobutamine stress echocardiography, in a patient with angiographically normal coronaries.

Authors:  Marios Ioannides; Kyriakos Yiangou; Theodoros Christodoulides; Marios Kassianides; Evagoras Nicolaides; Michael Henein
Journal:  Int J Cardiol       Date:  2007-09-19       Impact factor: 4.164

9.  Coronary artery spasm and dobutamine stress echocardiography.

Authors:  Falah Aboukhoudir; Sofiene Rekik; Stephane Andrieu; Saida Cheggour; Michel Pansieri; Marc Metge; Pierre Barnay; Jean Paul Faugier; Sylvie Schouvey; Gonzalo Quaino; Clement Unal; Stéphanie Gonzalez; Jean Lou Hirsch
Journal:  Eur J Echocardiogr       Date:  2009-02-06

10.  [Coronary Spasm after Administration of Propranolol during Dobutamine Stress Echocardiography].

Authors:  Lucía Alvarez; José Zamorano; Luis Mataix; Carlos Almeria; Raúl Moreno; José Luis Rodrigo
Journal:  Rev Esp Cardiol       Date:  2002-07       Impact factor: 4.753

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.