| Literature DB >> 32859174 |
Qin Luo1,2, Wenwen Xue1, Yin Yuan1, Chaowei Fu3, Jiangnan He1, Haidong Zou1,2, Xiaowei Tong1, Richard K Lee4, Ling Ge5,6.
Abstract
BACKGROUND: To investigate the distribution of peripheral anterior chamber depth (ACD) and the relationship between peripheral ACD and gonioscopy compared to other ocular parameters for primary angle closure disease (PACD) screening. We performed a population-based survey in Pudong New District of Shanghai, China, in 2011.Entities:
Keywords: Chinese; Peripheral anterior chamber depth; Primary angle closure disease; Screening
Mesh:
Year: 2020 PMID: 32859174 PMCID: PMC7456037 DOI: 10.1186/s12886-020-01618-3
Source DB: PubMed Journal: BMC Ophthalmol ISSN: 1471-2415 Impact factor: 2.209
Fig. 1Histogram showing distribution of peripheral ACD (mean, 0.94 CT; standard deviation, 0.44 CT) in 2463 right eyes
Characteristic of peripheral ACD in right eyes
| n | Mean ± SD | Median | 25th Percentile | 50th Percentile | 75th Percentile | Missing | Range | |
|---|---|---|---|---|---|---|---|---|
| 50–60 | 368 | 1.06 ± 0.47 | 1.00 | 0.72 | 1.00 | 1.37 | 0 | 0.18–2.93 |
| 60–70 | 398 | 1.02 ± 0.46 | 0.94 | 0.69 | 0.94 | 1.30 | 0 | 0.11–2.81 |
| 70–80 | 218 | 1.00 ± 0.44 | 0.94 | 0.67 | 0.94 | 1.24 | 0 | 0.21–2.60 |
| 80–94 | 52 | 1.11 ± 0.59 | 1.02 | 0.65 | 1.02 | 1.29 | 0 | 0.28–2.72 |
| All | 1036 | 1.04 ± 0.46 | 0.97 | 0.69 | 0.97 | 1.30 | 0 | 0.11–2.93 |
| 50–60 | 610 | 0.91 ± 0.40 | 0.85 | 0.63 | 0.85 | 1.11 | 0 | 0.12–2.65 |
| 60–70 | 497 | 0.84 ± 0.40 | 0.79 | 0.54 | 0.79 | 1.08 | 0 | 0.13–2.33 |
| 70–80 | 245 | 0.84 ± 0.44 | 0.75 | 0.54 | 0.75 | 1.06 | 0 | 0.17–2.85 |
| 80–94 | 75 | 0.94 ± 0.52 | 0.78 | 0.60 | 0.78 | 1.18 | 0 | 0.26–2.96 |
| All | 1427 | 0.87 ± 0.41 | 0.81 | 0.59 | 0.81 | 1.09 | 0 | 0.12–2.96 |
| 50–60 | 978 | 0.97 ± 0.43 | 0.90 | 0.65 | 0.90 | 1.21 | 0 | 0.12–2.93 |
| 60–70 | 895 | 0.92 ± 0.43 | 0.86 | 0.60 | 0.86 | 1.16 | 0 | 0.11–2.81 |
| 70–80 | 463 | 0.91 ± 0.45 | 0.83 | 0.60 | 0.83 | 1.15 | 0 | 0.17–2.85 |
| 80–94 | 127 | 1.01 ± 0.56 | 0.87 | 0.61 | 0.87 | 1.26 | 0 | 0.26–2.96 |
| All | 2463 | 0.94 ± 0.44 | 0.87 | 0.63 | 0.87 | 1.19 | 0 | 0.11–2.96 |
SD Standard deviation
Multivariate analysis of the association between peripheral ACD and other parameters
| Variable | Nonstandardized Regression Coefficient(95% CI) | Standardized Regression Coefficient | Variance Inflation Factor | |
|---|---|---|---|---|
| Intercept | 1.34 (1.17,1.51) | 0.00 | 0.00 | <.0001 |
| Age | −0.00 (−0.00,0.00) | −0.02 | 1.02 | 0.2112 |
| Gender | −0.17 (− 0.20,-0.13) | −0.19 | 1.01 | <.0001 |
| IOP | −0.00 (− 0.01,0.00) | −0.04 | 1.02 | 0.0605 |
| SE | −0.04 (− 0.05,-0.04) | −0.31 | 1.01 | <.0001 |
Peripheral ACD values and SE in 291 subjects with peripheral ACD less than 0.5 CT in right eyes
| Gender | Age | Peripheral ACD | SE | ||||
|---|---|---|---|---|---|---|---|
| n | Mean ± SD | Range | n | Mean ± SD | Range | ||
| 50–60 | 25 | 0.36 ± 0.09 | 0.18–0.49 | 25 | 0.93 ± 1.27 | −1.00-4.625 | |
| 60–70 | 28 | 0.37 ± 0.08 | 0.11–0.47 | 28 | 1.00 ± 1.61 | −5.375-3.75 | |
| 70–80 | 19 | 0.39 ± 0.08 | 0.21–0.48 | 16 | 0.09 ± 5.03 | −17.375-4.25 | |
| 80–94 | 5 | 0.43 ± 0.09 | 0.28–0.49 | 4 | 1.22 ± 2.12 | −1.625-3.50 | |
| subtotal | 77 | 0.37 ± 0.08 | 0.11–0.49 | 73 | 0.79 ± 2.67 | −17.375-4.625 | |
| 50–60 | 61 | 0.37 ± 0.10 | 0.12–0.49 | 60 | 0.78 ± 1.03 | −3.00-3.75 | |
| 60–70 | 91 | 0.35 ± 0.09 | 0.13–0.49 | 90 | 0.77 ± 1.53 | −8.25-3.875 | |
| 70–80 | 53 | 0.35 ± 0.09 | 0.17–0.49 | 49 | 0.96 ± 1.65 | −4.625-4.125 | |
| 80–94 | 9 | 0.33 ± 0.07 | 0.26–0.46 | 6 | 2.08 ± 1.43 | 0.50–4.25 | |
| subtotal | 214 | 0.35 ± 0.09 | 0.12–0.49 | 205 | 0.85 ± 1.44 | −8.25-4.25 | |
| 50–60 | 86 | 0.37 ± 0.09 | 0.12–0.49 | 85 | 0.82 ± 1.10 | −3.00-4.625 | |
| 60–70 | 119 | 0.35 ± 0.09 | 0.11–0.49 | 118 | 0.82 ± 1.55 | −8.25-3.875 | |
| 70–80 | 72 | 0.36 ± 0.09 | 0.17–0.49 | 65 | 0.74 ± 2.84 | −17.375-4.25 | |
| 80–94 | 14 | 0.37 ± 0.09 | 0.26–0.49 | 10 | 1.74 ± 1.68 | −1.625-4.25 | |
| total | 291 | 0.36 ± 0.09 | 0.11–0.49 | 278 | 0.84 ± 1.84 | −17.375-4.625 | |
AUC of different ROC curve and cut-off value
| ROC curve | AUC (95% CI) | Cut-off Value | Se | Sp | PV+ | Youden Index |
|---|---|---|---|---|---|---|
| peripheral ACD + SE | 0.786 (0.726, 0.847) | peripheral ACD =0.360 SE =2.120 | 0.809 | 0.670 | 0.527 | 0.479 |
| peripheral ACD | 0.777 (0.715, 0.839) | peripheral ACD =0.305 | 0.618 | 0.862 | 0.498 | 0.480 |
| SE | 0.547 (0.476, 0.619) | SE =1.188 | 0.652 | 0.468 | 0.346 | 0.120 |
AUC Area under curve, Se Sensitivity, Sp Specificity, PV+ Positive predictive value
Fig. 2ROC curves of different index for identifying PACD
The efficacy of identifying PACD with different peripheral ACD
| Peripheral ACD grade | Se | Sp | PV+ | Youden Index |
|---|---|---|---|---|
| < 0.2 | 0.154 | 0.995 | 0.933 | 0.100 |
| < 0.3 | 0.571 | 0.890 | 0.703 | 0.403 |
| < 0.4 | 0.846 | 0.475 | 0.423 | 0.291 |
| < 0.5 | 1.000 | 0.000 | 0.313 | 0.000 |