BACKGROUND: To determine whether preoperative hole diameter ratio (HDR) is a predictive factor for postoperative anatomical outcome for stage III or IV idiopathic macular holes (IMHs).Entities:
Keywords: Idiopathic macular hole; Internal limiting membrane peeling; Optical coherence tomography; Predictive factor; Vitrectomy
Mesh:
Year: 2020 PMID: 32859171 PMCID: PMC7456388 DOI: 10.1186/s12886-020-01614-7
Source DB: PubMed Journal: BMC Ophthalmol ISSN: 1471-2415 Impact factor: 2.209
Fig. 2This is a Chinese patient (60–70 years old) with an A-type idiopathic macular hole. The minimal diameter was 697 μm and maximum diameter was 1656 μm. The diameter of his macular hole was “large”, but the hole diameter ratio was less than 0.6. The MH was closed at postoperative 1 month
Fig. 3This is a Chinese patient (60–70 years old) with a H-type idiopathic macular hole. The minimal diameter was 681 μm and maximum diameter was 1080 μm. The preoperative diameter of her macular hole was similar with the patient in Fig. 2, but the hole diameter ratio was more than 0.6. The macular hole was unclosed at postoperative 3 months
Comparison of Pre-operative Characteristics in Two Groups
| Group A | Group B | t | P | |
|---|---|---|---|---|
| Eyes | 81 | 20 | ||
| Age (years) | 64.1 ± 4.4 | 67.0 ± 4.5 | −0.9 | 0.32 |
| Duration of symptoms (months) | 8.3 ± 11.1 | 8.3 ± 3.9 | −0.9 | 0.38 |
| PreopBCVA (LogMAR) | 1.1 ± 0.4 | 1.0 ± 0.4 | −0.4 | 0.68 |
| IOP (mmHg) | 15.5 ± 2.8 | 16.0 ± 3.5 | 0.2 | 0.46 |
| Axial Length (mm) | 23.4 ± 0.7 | 22.9 ± 0.7 | 0.2 | 0.24 |
| Minimum Diameter (μm) | 597.6 ± 120.1 | 703.6 ± 116.1 | −3.6 | < 0.01 |
| Maximum Diameter (μm) | 1144.6 ± 182.0 | 1232.2 ± 186.3 | −1.9 | 0.58 |
| HDR | 0.5 ± 0.1 | 0.6 ± 0.1 | −1.9 | 0.03 |
Group A: eyes with closed MH; Group B: eyes with unclosed MH
BCVA: best corrected visual acuity; IOP: intra-ocular pressure
Fig. 1The area under the receiver operating characteristic curve of preoperative hole diameter ratio (HDR) for predicting postoperative macular hole closure. The area under the curve was 0.680 (95% confidence interval 0.559–0.801). When the cutoff value of HDR was set at 0.6, the predicting sensitivity and specificity were 75.0 and 67.9%, respectively (P = 0.01)
Comparation of two type IMHs between group A and B
| A-Type IMH | H-Type IMH | t | P | ||
|---|---|---|---|---|---|
| Group A | N (%) | 55 (67.9) | 26 (32.1) | ||
| Diametera (μm) | 559.0 ± 102.9 | 679.1 ± 114.6 | −4.7 | 0.000 | |
| HDR | 0.5 ± 0.1 | 0.6 ± 0.1 | |||
| Group B | N (%) | 6 (30) | 14 (70) | ||
| Diametera (μm) | 639.7 ± 137.5 | 731.0 ± 98.7 | −1.7 | 0.11 | |
| HDR | 0.5 ± 0.02 | 0.6 ± 0.04 | |||
| Mean Diametera (μm) | 567.0 ± 108.2 | 697.3 ± 110.9 | −5.9 | 0.000 | |
| Comparation of Diametera between group A and B | t | −1.8 | −1.4 | ||
| P | 0.1 | 0.2 | |||
| Comparation of HDR between group A and B | t | −0.9 | 1.0 | ||
| P | 0.4 | 0.3 | |||
IMH idiopathic macular hole