Literature DB >> 32858741

Patients' and Physicians' Knowledge of Radiation Exposure Related to Spine Surgery.

Michelle C Scott1, Anoop R Galivanche2, Elbert J Mets2, Neil Pathak2, Joseph B Kahan2, Patrick J Burroughs2, Arya G Varthi2, Lee E Rubin2, Jonathan N Grauer2.   

Abstract

STUDY
DESIGN: Cross-sectional survey.
OBJECTIVE: Examine patients' and physicians' estimates of radiation exposure related to spine surgery. SUMMARY OF BACKGROUND DATA: Patients are commonly exposed to radiation when undergoing spine surgery. Previous studies suggest that patients and physicians have limited knowledge about radiation exposure in the outpatient setting. This has not been assessed for intraoperative imaging.
METHODS: A questionnaire was developed to assess awareness/knowledge of radiation exposure in outpatient and intraoperative spine care settings. Patients and surgeons estimated chest radiograph (CXR) equivalent radiation from: cervical and lumbar radiographs (anterior-posterior [AP] and lateral), computed tomography (CT), magnetic resonance imaging (MRI), intraoperative fluoroscopy, and intraoperative CT (O-arm). Results were compared to literature-reported radiation doses.
RESULTS: Overall, 100 patients and 26 providers completed the survey. Only 31% of patients were informed about outpatient radiation exposure, and only 23% of those who had undergone spine surgery had been informed about intraoperative radiation exposure. For lumbar radiographs, patients and surgeons underestimated CXR-equivalent radiation exposures: AP by five-fold (P < 0.0001) and seven-fold (P < 0.0001), respectively, and lateral by three-fold (P < 0.0001) and four-fold (P = 0.0002), respectively. For cervical CT imaging, patients and surgeons underestimated radiation exposure by 18-fold (P < 0.0001) and two-fold (P = 0.0339), respectively. For lumbar CT imaging, patients and surgeons underestimated radiation exposure by 31-fold (P < 0.0001) and three-fold (P = 0.0001), respectively. For intraoperative specific cervical and lumbar imaging, patients underestimated radiation exposure for O-arm by 11-fold (P < 0.0001) and 22-fold (P = 0.0002), respectively. Surgeons underestimated radiation exposure of lumbar O-arm by three-fold (P = 0.0227).
CONCLUSION: This study evaluated patient and physician knowledge of radiation exposure related to spine procedures. Underestimation of radiation exposure in the outpatient setting was consistent with prior study findings. The significant underestimation of intraoperative cross-sectional imaging (O-arm) is notable and needs attention in the era of increased use of such technology for imaging, navigation, and robotic spine surgery. LEVEL OF EVIDENCE: 4.

Entities:  

Mesh:

Year:  2020        PMID: 32858741     DOI: 10.1097/BRS.0000000000003650

Source DB:  PubMed          Journal:  Spine (Phila Pa 1976)        ISSN: 0362-2436            Impact factor:   3.241


  3 in total

1.  Puncture and localization for percutaneous endoscopic lumbar discectomy with C-arm navigation: a randomized controlled cadaver trial.

Authors:  Hao Qin; Li Deng; Lin Xu; Qingchun Mu; Xiang Luo; Shengbin Huang; Maosheng Wang; Chunmei Luo; Chunming Huang; Wenhua Huang
Journal:  Ann Transl Med       Date:  2021-12

2.  A deep learning algorithm to identify cervical ossification of posterior longitudinal ligaments on radiography.

Authors:  Koji Tamai; Hidetomi Terai; Masatoshi Hoshino; Akito Yabu; Hitoshi Tabuchi; Ryo Sasaki; Hiroaki Nakamura
Journal:  Sci Rep       Date:  2022-02-08       Impact factor: 4.379

3.  A comparative study of single and double incision for L4/5 and L5/S1 double-level percutaneous interlaminar lumbar discectomy.

Authors:  Yingchuang Tang; Zixiang Liu; Hao Liu; Junxin Zhang; Xiaoyu Zhu; Zhonglai Qian; Huilin Yang; Haiqing Mao; Kai Zhang; Hao Chen; Kangwu Chen
Journal:  Front Surg       Date:  2022-08-30
  3 in total