Literature DB >> 3285667

Random donor platelet crossmatching: comparison of four platelet antibody detection methods.

J Freedman1, M B Garvey, Z Salomon de Friedberg, A Hornstein, V Blanchette.   

Abstract

The standard lymphocytotoxicity assay (LCT), a biotin-avidin enzyme immunoassay (ELISA), platelet suspension immunofluorescence test (PSIFT), and platelet radioactive antiglobulin test (PRAT) were examined in prospective crossmatching for selection of compatible random donor platelets for refractory patients. One hundred seven episodes of pooled random donor platelet transfusions were evaluated in 26 patients. There was good reproducibility of results by individual techniques. Concordance of results by the different methods was 40-60%. One-hour and 24 hr posttransfusion corrected count increments (CCI) were compared as parameters for assessing success or failure of the transfusion. Using a rank scoring system, the relative efficiency of predictiveness for all transfusions was PRAT greater than LCT greater than PSIFT greater than ELISA. Combination of PRAT and LCT afforded the best predictability and sensitivity was higher than for either PRAT or LCT alone (93 vs. 79 and 62%, respectively). Mean posttransfusion CCI (x 10(9)/L) following PRAT-compatible platelets was 13.9 +/- 12.7 at 1 hr and 7.3 +/- 6.9 at 24 hr; following PRAT-incompatible platelets, 5.7 +/- 7.8 (1 hr) and 2.1 +/- 4.1 (24 hr). Results were similar for LCT-tested platelets. A radioimmunofiltration modification of the PRAT developed and used in selected cases was simple, fast, efficient, and inexpensive. The study indicated that the techniques evaluated are practical and feasible for routine use in the provision of compatible random donor platelets to the refractory patient who has no other cause for increased platelet destruction.

Entities:  

Mesh:

Substances:

Year:  1988        PMID: 3285667     DOI: 10.1002/ajh.2830280102

Source DB:  PubMed          Journal:  Am J Hematol        ISSN: 0361-8609            Impact factor:   10.047


  3 in total

1.  Cross-match-compatible platelets improve corrected count increments in patients who are refractory to randomly selected platelets.

Authors:  Priti Elhence; Rajendra K Chaudhary; Soniya Nityanand
Journal:  Blood Transfus       Date:  2013-11-14       Impact factor: 3.443

2.  Evaluation of platelet cross-matching in the management of patients refractory to platelet transfusions.

Authors:  Osama S Salama; Doaa A Aladl; Doaa M El Ghannam; Wesam E Elderiny
Journal:  Blood Transfus       Date:  2014-04       Impact factor: 3.443

3.  Flow cytometric immunobead assay for quantitative detection of platelet autoantibodies in immune thrombocytopenia patients.

Authors:  Juping Zhai; Mengyuan Ding; Tianjie Yang; Bin Zuo; Zhen Weng; Yunxiao Zhao; Jun He; Qingyu Wu; Changgeng Ruan; Yang He
Journal:  J Transl Med       Date:  2017-10-23       Impact factor: 5.531

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.