Literature DB >> 32853114

Ventilatory heterogeneity in the normal human lung is unchanged by controlled breathing.

G Kim Prisk1, Gregory M Petersen1, Eric T Geier1, Rui C Sá1.   

Abstract

Measurement of ventilation heterogeneity with the multiple-breath nitrogen washout (MBW) is usually performed using controlled breathing with a fixed tidal volume and breathing frequency. However, it is unclear whether controlled breathing alters the underlying ventilatory heterogeneity. We hypothesized that the width of the specific ventilation distribution (a measure of heterogeneity) would be greater in tests performed during free breathing compared with those performed using controlled breathing. Eight normal subjects (age range = 23-50 yr, 5 female/3 male) twice underwent MRI-based specific ventilation imaging consisting of five repeated cycles with the inspired gas switching between 21% and 100% O2 every ~2 min (total imaging time = ~20 min). In each session, tests were performed with free breathing (FB, no constraints) and controlled breathing (CB) at a respiratory rate of 12 breaths/min and no tidal volume control. The specific ventilation (SV) distribution in a mid-sagittal slice of the right lung was calculated, and the heterogeneity was calculated as the full width at half max of a Gaussian distribution fitted on a log scale (SV width). Free breathing resulted in a range of breathing frequencies from 8.7 to 15.9 breaths/min (mean = 11.5 ± 2.2, P = 0.62, compared with CB). Heterogeneity (SV width) was unchanged by controlled breathing (FB: 0.38 ± 0.12; CB: 0.34 ± 0.09, P = 0.18, repeated-measures ANOVA). The imposition of a controlled breathing frequency did not significantly affect the heterogeneity of ventilation in the normal lung, suggesting that MBW and specific ventilation imaging as typically performed provide an unperturbed measure of ventilatory heterogeneity.NEW & NOTEWORTHY By using MRI-based specific ventilation imaging (SVI), we showed that the heterogeneity of specific ventilation was not different comparing free breathing and breathing with the imposition of a fixed breathing frequency of 12 breaths/min. Thus, multiple-breath washout and SVI as typically performed provide an unperturbed measure of ventilatory heterogeneity.

Entities:  

Keywords:  MBW; SVI; washout

Mesh:

Year:  2020        PMID: 32853114      PMCID: PMC7701356          DOI: 10.1152/japplphysiol.00278.2020

Source DB:  PubMed          Journal:  J Appl Physiol (1985)        ISSN: 0161-7567


  28 in total

1.  Relationships between the lung clearance index and conductive and acinar ventilation heterogeneity.

Authors:  Sylvia Verbanck; Manuel Paiva; Daniel Schuermans; Shane Hanon; Walter Vincken; Alain Van Muylem
Journal:  J Appl Physiol (1985)       Date:  2011-12-08

2.  Affine transformation registers small scale lung deformation.

Authors:  Tatsuya J Arai; Christopher T Villongco; Michael T Villongco; Susan R Hopkins; Rebecca J Theilmann
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2012

3.  Consensus statement for inert gas washout measurement using multiple- and single- breath tests.

Authors:  Paul D Robinson; Philipp Latzin; Sylvia Verbanck; Graham L Hall; Alexander Horsley; Monika Gappa; Cindy Thamrin; Hubertus G M Arets; Paul Aurora; Susanne I Fuchs; Gregory G King; Sooky Lum; Kenneth Macleod; Manuel Paiva; Jane J Pillow; Sarath Ranganathan; Sarah Ranganathan; Felix Ratjen; Florian Singer; Samatha Sonnappa; Janet Stocks; Padmaja Subbarao; Bruce R Thompson; Per M Gustafsson
Journal:  Eur Respir J       Date:  2013-02-08       Impact factor: 16.671

4.  Validating the distribution of specific ventilation in healthy humans measured using proton MR imaging.

Authors:  Rui Carlos Sá; Amran K Asadi; Rebecca J Theilmann; Susan R Hopkins; G Kim Prisk; Chantal Darquenne
Journal:  J Appl Physiol (1985)       Date:  2014-02-06

5.  Variability of resting respiratory drive and timing in healthy subjects.

Authors:  M J Tobin; M J Mador; S M Guenther; R F Lodato; M A Sackner
Journal:  J Appl Physiol (1985)       Date:  1988-07

6.  Predicted values for closing volumes using a modified single breath nitrogen test.

Authors:  A S Buist; B B Ross
Journal:  Am Rev Respir Dis       Date:  1973-05

7.  Continuous distributions of specific ventilation recovered from inert gas washout.

Authors:  S M Lewis; J W Evans; A A Jalowayski
Journal:  J Appl Physiol Respir Environ Exerc Physiol       Date:  1978-03

8.  Pendelluft in the bronchial tree.

Authors:  Elliot E Greenblatt; James P Butler; Jose G Venegas; Tilo Winkler
Journal:  J Appl Physiol (1985)       Date:  2014-08-28

9.  In silico modeling of oxygen-enhanced MRI of specific ventilation.

Authors:  Wendy Kang; Merryn H Tawhai; Alys R Clark; Rui C Sá; Eric T Geier; G Kim Prisk; Kelly S Burrowes
Journal:  Physiol Rep       Date:  2018-04

10.  Comparison of quantitative multiple-breath specific ventilation imaging using colocalized 2D oxygen-enhanced MRI and hyperpolarized 3He MRI.

Authors:  Tatsuya J Arai; Felix C Horn; Rui Carlos Sá; Madhwesha R Rao; Guilhem J Collier; Rebecca J Theilmann; G Kim Prisk; Jim M Wild
Journal:  J Appl Physiol (1985)       Date:  2018-08-30
View more
  2 in total

1.  Breathing freely during nitrogen washout.

Authors:  Gabriel C Motta-Ribeiro; Tilo Winkler
Journal:  J Appl Physiol (1985)       Date:  2020-10-22

2.  Measuring short-term changes in specific ventilation using dynamic specific ventilation imaging.

Authors:  Eric T Geier; G Kim Prisk; Rui C Sá
Journal:  J Appl Physiol (1985)       Date:  2022-04-28
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.