Danijel Domic1,2, Kristina Bertl1,2, Salman Ahmad1, Lars Schropp3, Kristina Hellén-Halme4, Andreas Stavropoulos1,5,6. 1. Department of Periodontology, Faculty of Odontology, University of Malmö, Malmö, Sweden. 2. Division of Oral Surgery, University Clinic of Dentistry, Medical University of Vienna, Vienna, Austria. 3. Section of Oral Radiology, Department of Dentistry and Oral Health, Aarhus University, Aarhus, Denmark. 4. Department of Oral and Maxillofacial Radiology, Faculty of Odontology, University of Malmö, Malmö, Sweden. 5. Division of Conservative Dentistry and Periodontology, University Clinic of Dentistry, Medical University of Vienna, Vienna, Austria. 6. Division of Regenerative Dentistry and Periodontology, University Clinics of Dental Medicine (CUMD), University of Geneva, Geneva, Switzerland.
Abstract
BACKGROUND: To evaluate whether buccal bone thickness (BBT), implant diameter, and abutment/crown material influence the accuracy of cone-beam computed tomography (CBCT) to determine the buccal bone level at titanium implants. METHODS: Two implant beds (i.e., narrow and standard diameter) were prepared in each of 36 porcine bone blocks. The implant beds were positioned at a variable distance from the buccal bone surface; thus, resulting in three BBT groups (i.e., >0.5 to 1.0; >1.0 to 1.5; >1.5 to 2.0 mm). In half of the blocks, a buccal bone dehiscence of random extent ("depth") was created and implants were mounted with different abutment/crown material (i.e., titanium abutments with a metal-ceramic crown and zirconia abutments with an all-ceramic zirconia crown). The distance from the implant shoulder to the buccal bone crest was measured on cross-sectional CBCT images and compared with the direct measurements at the bone blocks. RESULTS: While abutment/crown material and implant diameter had no effect on the detection accuracy of the buccal bone level at dental implants in CBCT scans, BBT had a significant effect. Specifically, when BBT was ≤1.0 mm, a dehiscence was often diagnosed although not present, that is, the sensitivity was high (95.8%), but the specificity (12.5%) and the detection accuracy (54.2%) were low. Further, the average measurement error of the distance from the implant shoulder to the buccal bone crest was 1.6 mm. CONCLUSIONS: Based on the present laboratory study, BBT has a major impact on the correct diagnosis of the buccal bone level at dental titanium implants in CBCT images; in cases where the buccal bone is ≤1 mm thick, detection of the buccal bone level is largely inaccurate.
BACKGROUND: To evaluate whether buccal bone thickness (BBT), implant diameter, and abutment/crown material influence the accuracy of cone-beam computed tomography (CBCT) to determine the buccal bone level at titanium implants. METHODS: Two implant beds (i.e., narrow and standard diameter) were prepared in each of 36 porcine bone blocks. The implant beds were positioned at a variable distance from the buccal bone surface; thus, resulting in three BBT groups (i.e., >0.5 to 1.0; >1.0 to 1.5; >1.5 to 2.0 mm). In half of the blocks, a buccal bone dehiscence of random extent ("depth") was created and implants were mounted with different abutment/crown material (i.e., titanium abutments with a metal-ceramic crown and zirconia abutments with an all-ceramic zirconia crown). The distance from the implant shoulder to the buccal bone crest was measured on cross-sectional CBCT images and compared with the direct measurements at the bone blocks. RESULTS: While abutment/crown material and implant diameter had no effect on the detection accuracy of the buccal bone level at dental implants in CBCT scans, BBT had a significant effect. Specifically, when BBT was ≤1.0 mm, a dehiscence was often diagnosed although not present, that is, the sensitivity was high (95.8%), but the specificity (12.5%) and the detection accuracy (54.2%) were low. Further, the average measurement error of the distance from the implant shoulder to the buccal bone crest was 1.6 mm. CONCLUSIONS: Based on the present laboratory study, BBT has a major impact on the correct diagnosis of the buccal bone level at dental titanium implants in CBCT images; in cases where the buccal bone is ≤1 mm thick, detection of the buccal bone level is largely inaccurate.