Literature DB >> 32844506

Acoustic analysis to monitor implant seating and early detect fractures in cementless THA: An in vivo study.

Quentin Goossens1, Leonard Pastrav1, Jorg Roosen2, Michiel Mulier2, Wim Desmet3, Jos Vander Sloten1, Kathleen Denis1.   

Abstract

The initial stability of cementless total hip arthroplasty (THA) implants is obtained by an interference fit that allows osseointegration for a long term secondary stability of the implant. Yet, finding the insertion endpoint that corresponds to an appropriate initial stability is currently often based on a number of subjective experiences of the orthopedic surgeon, which can be challenging. In order to assist the orthopedic surgeons in their pursuit to find this optimal initial stability, this study aims to determine whether the analysis of sound that results from the implant insertion hammer blows can be used to objectively monitor the insertion process of cementless THA implants. An in vivo study was conducted. The experimental results revealed vibro-acoustic behavior sensitive to implant seating, related to the low frequency content of the response spectra. This sensitive low-frequency behavior was quantified by a set of specific vibro-acoustic features and metrics that reflected the power and similarity of the low-frequency response. These features and metrics allowed monitoring the implant seating and their convergence agreed well with the endpoint of insertion as determined by the orthopedic surgeon. Intraoperative fractures caused an abrupt and opposite change of the vibro-acoustic behavior prior to the notification of the fracture by the orthopedic surgeon. The observation of such an abrupt change in the vibro-acoustic behavior can be an important early warning for loss of implant stability. The presented vibro-acoustic measurement method shows potential to serve as a decision supporting source of information as it showed to reflect the implant seating.
© 2020 Orthopaedic Research Society. Published by Wiley Periodicals LLC.

Entities:  

Keywords:  cementless total hip arthroplasty; primary implant stability; vibro-acoustic analysis

Year:  2020        PMID: 32844506     DOI: 10.1002/jor.24837

Source DB:  PubMed          Journal:  J Orthop Res        ISSN: 0736-0266            Impact factor:   3.494


  5 in total

1.  Modal Analysis of the Ancillary During Femoral Stem Insertion: A Study on Bone Mimicking Phantoms.

Authors:  Anne-Sophie Poudrel; Giuseppe Rosi; Vu-Hieu Nguyen; Guillaume Haiat
Journal:  Ann Biomed Eng       Date:  2022-01-07       Impact factor: 3.934

2.  Replacement of Destructive Pull-out Test with Modal Analysis in Primary Fixation Stability Assessment of Spinal Pedicle Screw.

Authors:  Mohammadjavad Einafshar; Ata Hashemi; Gerrit Harry van Lenthe
Journal:  Arch Bone Jt Surg       Date:  2022-02

3.  Development of an Instrument to Assess the Stability of Cementless Femoral Implants Using Vibration Analysis During Total Hip Arthroplasty.

Authors:  Steven Leuridan; Quentin Goossens; Leonard Cezar Pastrav; Michiel Mulier; Wim Desmet; Jos Vander Sloten; Kathleen Denis
Journal:  IEEE J Transl Eng Health Med       Date:  2021-11-15       Impact factor: 3.316

4.  Using Acoustic Vibrations as a Method for Implant Insertion Assessment in Total Hip Arthroplasty.

Authors:  Jonathan C J Wei; Willem H A Crezee; Hilda Jongeneel; Tobias S A De Haas; Wesley L A Kool; Bryan J Blaauw; Jenny Dankelman; Tim Horeman
Journal:  Sensors (Basel)       Date:  2022-02-18       Impact factor: 3.576

5.  A parametric numerical analysis of femoral stem impaction.

Authors:  Nicholas E Bishop; Phil Wright; Martin Preutenborbeck
Journal:  PLoS One       Date:  2022-05-20       Impact factor: 3.240