Pneumatic anti-shock garment: state of the art 1988.

N E McSwain1.   

Abstract

The responses of hypovolemic patients would be expected to be similar to experimental animals that were hypovolemic. Normovolemic patients would be expected to respond as do the normovolemic experimental animals. Hypovolemic patients do not necessarily respond the same as do normovolemic patients or volunteers. The amount of external pressure applied by the device is directly proportional to the amount of tissue pressure increase. Tissue pressure is transmitted to the vessel as reduction transmural pressure, or in change in the size of the vessels and subsequent increase in SVR. Patient response to external pressure varies with the amount of device pressure. The optimal pressure of the PASG is in the range of 60 to 80 torr. Although exceeding this value does not appear to be necessary, it is not harmful in the short term (less than 90 minutes). Using less pressure reduces the SVR and, therefore, the blood pressure response. Keeping the external pressure at approximately 40 torr appears to be ideal for hemorrhage control. Of the more than 300 articles that have appeared in the recent literature addressing the PASG, at least 190 have discussed specific scientific experiments in the animal laboratory, in the human laboratory, or in the clinical environment, in which results gathered addressed how, why, or if the PASG worked. These studies demonstrate that the PASG does, in fact, improve blood pressure, control hemorrhage, improve carotid and upper body blood flow, improve the ability of the prehospital provider to start IV lines, and improve survival (particularly short-term) with few hospital and even fewer prehospital complications. The device produces its blood pressure response by improving preload, increasing SVR, and mobilizing some blood (500 to 1,000 mL) to the upper body compartment above the device. These responses are most probably produced by decreasing the radius of the vessels compressed by the device, decreasing the compartment volume, and differentially affecting the blood flow without and within the device. Hemorrhage is controlled by increasing the external pressure on the vessel by the transmitted increased tissue pressure, reducing the vascular lumen, and reducing the area of the laceration. Short-term survival is improved by decreasing intra-abdominal hemorrhage and improving perfusion (maintaining better oxygenation in the heart-brain-lung circulation.) Long-term survival is improved because the device controls hemorrhage, maintains blood pressure, and allows delivery of the severely injured patient to the trauma center and within the hospital while awaiting an OR, as in the case of a leaking aortic aneurysm.(ABSTRACT TRUNCATED AT 400 WORDS)

Entities:  

Mesh:

Year:  1988        PMID: 3284422     DOI: 10.1016/s0196-0644(88)80248-8

Source DB:  PubMed          Journal:  Ann Emerg Med        ISSN: 0196-0644            Impact factor:   5.721


  7 in total

Review 1.  Accident and emergency medicine--II.

Authors:  R C Evans; R J Evans
Journal:  Postgrad Med J       Date:  1992-10       Impact factor: 2.401

Review 2.  Emergent management of pelvic ring injuries: an update.

Authors:  Khitish Mohanty; Damian Musso; James N Powell; John B Kortbeek; Andrew W Kirkpatrick
Journal:  Can J Surg       Date:  2005-02       Impact factor: 2.089

3.  Military antishock garment reevaluated.

Authors:  B Z Horowitz
Journal:  West J Med       Date:  1989-07

4.  An inexpensive device to treat postpartum hemorrhage: a preliminary proof of concept study of health provider opinion and training in Nepal.

Authors:  Nancy L Kerr; Mark Hauswald; Suman Raj Tamrakar; David A Wachter; Gillian M Baty
Journal:  BMC Pregnancy Childbirth       Date:  2014-02-24       Impact factor: 3.007

5.  History and significance of the trauma resuscitation flow sheet.

Authors:  Julie A Dunn; Thomas J Schroeppel; Michael Metzler; Chris Cribari; Katherine Corey; David R Boyd
Journal:  Trauma Surg Acute Care Open       Date:  2018-10-09

6.  Postoperative gastric dilatation causing abdominal compartment syndrome.

Authors:  Ahmad Mahajna; Sharon Mitkal; Michael M Krausz
Journal:  World J Emerg Surg       Date:  2008-01-31       Impact factor: 5.469

7.  Non-pneumatic anti-shock garment (NASG), a first-aid device to decrease maternal mortality from obstetric hemorrhage: a cluster randomized trial.

Authors:  Suellen Miller; Eduardo F Bergel; Alison M El Ayadi; Luz Gibbons; Elizabeth A Butrick; Thulani Magwali; Gricelia Mkumba; Christine Kaseba; N T My Huong; Jillian D Geissler; Mario Merialdi
Journal:  PLoS One       Date:  2013-10-23       Impact factor: 3.240

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.