Literature DB >> 32843090

Optic nerve sheath diameter guided detection of sepsis-associated encephalopathy.

Varun Suresh1.   

Abstract

Entities:  

Mesh:

Year:  2020        PMID: 32843090      PMCID: PMC7449064          DOI: 10.1186/s13054-020-03232-7

Source DB:  PubMed          Journal:  Crit Care        ISSN: 1364-8535            Impact factor:   9.097


× No keyword cloud information.
I read with interest the research work done by Yang and colleagues [1] on measurement of ultrasonography-guided optic nerve sheath diameter (ONSD) in sepsis-associated encephalopathy (SAE) and its correlation with outcome. I appreciate the authors for successfully demonstrating raised ONSD in SAE patients; however, I have a few methodological concerns with the study. The difference in ONSD across the three population groups compared in the study is sub-millimetric. Thus, an investigator not blinded to patient clinical condition can be biased to overestimate ONSD in SAE cases. This being a serious limitation authors could have sought for options of blinded ONSD measurements. It is also understood from the study results that elderly patients were included in the study population. A septated or trabeculated ONS being very common in elderly [2] such inclusion need not have essentially reflected the true ONSD. I also wonder why a correlation between ONSD and serum albumin level was calculated. It is a very well-known fact that the blood-brain barrier is an osmotic interface [3] and oncotic pressure differences do not reflect on intracranial pressure. Do the authors essentially mean that hypoalbuminemia causes cerebral edema which indirectly reflects as high ONSD? It is inferred that this particular finding could be a statistical debate with zero clinical relevance. Further, there is a considerable “blooming effect” artifact [4] in the ONSD images demonstrated by authors which could have affected the true ONSD measurements. Since majority of patients with SAE were on mechanical ventilation, a description of positive end-expiratory pressure and end-tidal carbon dioxide levels, which can directly affect ONSD [5], is distinctly wanted in the study results to exclude these confounders. Unarguably Yang and colleagues’ effort on demonstrating ONSD threshold of ≥ 5.5 mm for detection of SAE is a novel contribution to knowledge, yet a narration on the concerns described here could have added more to the lucidity of author’s data.
  5 in total

1.  Optic Nerve Sheath Diameter Ultrasound: Optic Nerve Growth Curve and its Application to Detect Intracranial Hypertension in Children.

Authors:  Maddalena De Bernardo; Livio Vitiello; Nicola Rosa
Journal:  Am J Ophthalmol       Date:  2019-10-11       Impact factor: 5.258

2.  Papilledema revisited: is its pathophysiology really understood?

Authors:  Hanspeter E Killer; Gregor P Jaggi; Neil R Miller
Journal:  Clin Exp Ophthalmol       Date:  2009-07       Impact factor: 4.207

Review 3.  Development, maintenance and disruption of the blood-brain barrier.

Authors:  Birgit Obermeier; Richard Daneman; Richard M Ransohoff
Journal:  Nat Med       Date:  2013-12-05       Impact factor: 53.440

4.  Bedside ultrasound measurement of optic nerve sheath diameter in patients with sepsis: a prospective observational study.

Authors:  Ziyue Yang; Cuihong Qin; Shuguang Zhang; Shaohua Liu; Tongwen Sun
Journal:  Crit Care       Date:  2020-05-18       Impact factor: 9.097

5.  A study to evaluate effect of PEEP and end-tidal carbon dioxide on optic nerve sheath diameter.

Authors:  Renu Bala; Rajesh Kumar; Jyoti Sharma
Journal:  Indian J Anaesth       Date:  2019-07
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.