Literature DB >> 32842726

Assessment of the Potential and Limitations of Elemental Mass Spectrometry in Life Sciences for Absolute Quantification of Biomolecules Using Generic Standards.

Laura Cid-Barrio1, Francisco Calderón-Celis1, José Manuel Costa-Fernández1, Jorge Ruiz Encinar1.   

Abstract

Inductively coupled plasma-mass spectrometry (ICP-MS) has been widely used in Life Sciences for the absolute quantification of biomolecules without specific standards, assuming the same response for generic compounds including complex biomolecules. However, contradictory results have been published on this regard. We present the first critical statistical comparison of the ICP-MS response factors obtained for 14 different relevant S-containing biomolecules (three peptides, four proteins, one amino acid, two cofactors, three polyethylene glycol (PEG) derivatives, and sulfate standard), covering a wide range of hydrophobicities and molecular sizes. Two regular flow nebulizers and a total consumption nebulizer (TCN) were tested. ICP-MS response factors were determined though calibration curves, and isotope dilution analysis was used to normalize the results. No statistical differences have been found for low-molecular-weight biocompounds, PEGs, and nonhydrophobic peptides using any of the nebulizers tested. Interestingly, while statistical differences were still found negligible (96-104%) for the proteins and hydrophobic peptide using the TCN, significantly lower response factors (87-40%) were obtained using regular flow nebulizers. Such differential behavior seems to be related mostly to hydrophobicity and partially to the molecular weight. Findings were validated using IDA in intact and digested bovine serum albumin solutions using the TCN (98 and 100%, respectively) and the concentric nebulizer (73 and 97%, respectively). Additionally, in the case of a phosphoprotein, results were corroborated using the P trace in parallel to the S trace used along the manuscript. This work seems to suggest that ICP-MS operated with regular nebulizers can offer absolute quantification using generic standards for most biomolecules except proteins and hydrophobic peptides.

Entities:  

Mesh:

Substances:

Year:  2020        PMID: 32842726     DOI: 10.1021/acs.analchem.0c02942

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  2 in total

1.  Signal amplification strategies for clinical biomarker quantification using elemental mass spectrometry.

Authors:  Andrea L Larraga-Urdaz; Maria L Fernandez Sanchez; Jorge Ruiz Encinar; Jose M Costa-Fernandez
Journal:  Anal Bioanal Chem       Date:  2021-03-05       Impact factor: 4.142

2.  Combined Molecular and Elemental Mass Spectrometry Approaches for Absolute Quantification of Proteomes: Application to the Venomics Characterization of the Two Species of Desert Black Cobras, Walterinnesia aegyptia and Walterinnesia morgani.

Authors:  Juan J Calvete; Davinia Pla; Johannes Els; Salvador Carranza; Maik Damm; Benjamin-Florian Hempel; Elisa B O John; Daniel Petras; Paul Heiss; Ayse Nalbantsoy; Bayram Göçmen; Roderich D Süssmuth; Francisco Calderón-Celis; Alicia Jiménez Nosti; Jorge Ruiz Encinar
Journal:  J Proteome Res       Date:  2021-10-04       Impact factor: 4.466

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.