Literature DB >> 32838471

A Risk Score for Predicting the Incidence of Hemorrhage in Critically Ill Neonates: Development and Validation Study.

Rozeta Sokou1, Daniele Piovani2,3, Aikaterini Konstantinidi1, Andreas G Tsantes4, Stavroula Parastatidou1, Maria Lampridou1, Georgios Ioakeimidis1, Antonis Gounaris5, Nicoletta Iacovidou6, Anastasios G Kriebardis7, Marianna Politou8, Petros Kopterides9, Stefanos Bonovas2,3, Argirios E Tsantes4.   

Abstract

The aim of the study was to develop and validate a prediction model for hemorrhage in critically ill neonates which combines rotational thromboelastometry (ROTEM) parameters and clinical variables. This cohort study included 332 consecutive full-term and preterm critically ill neonates. We performed ROTEM and used the neonatal bleeding assessment tool (NeoBAT) to record bleeding events. We fitted double selection least absolute shrinkage and selection operator logit regression to build our prediction model. Bleeding within 24 hours of the ROTEM testing was the outcome variable, while patient characteristics, biochemical, hematological, and thromboelastometry parameters were the candidate predictors of bleeding. We used both cross-validation and bootstrap as internal validation techniques. Then, we built a prognostic index of bleeding by converting the coefficients from the final multivariable model of relevant prognostic variables into a risk score. A receiver operating characteristic analysis was used to calculate the area under curve (AUC) of our prediction index. EXTEM A10 and LI60, platelet counts, and creatinine levels were identified as the most robust predictors of bleeding and included them into a Neonatal Bleeding Risk (NeoBRis) index. The NeoBRis index demonstrated excellent model performance with an AUC of 0.908 (95% confidence interval [CI]: 0.870-0.946). Calibration plot displayed optimal calibration and discrimination of the index, while bootstrap resampling ensured internal validity by showing an AUC of 0.907 (95% CI: 0.868-0.947). We developed and internally validated an easy-to-apply prediction model of hemorrhage in critically ill neonates. After external validation, this model will enable clinicians to quantify the 24-hour bleeding risk. Thieme. All rights reserved.

Entities:  

Year:  2020        PMID: 32838471     DOI: 10.1055/s-0040-1715832

Source DB:  PubMed          Journal:  Thromb Haemost        ISSN: 0340-6245            Impact factor:   5.249


  6 in total

1.  Hemostatic Evaluation With Viscoelastic Coagulation Monitor: A Nicu Experience.

Authors:  Giacomo Simeone Amelio; Genny Raffaeli; Ilaria Amodeo; Silvia Gulden; Valeria Cortesi; Francesca Manzoni; Nicola Pesenti; Stefano Ghirardello; Fabio Mosca; Giacomo Cavallaro
Journal:  Front Pediatr       Date:  2022-05-10       Impact factor: 3.569

Review 2.  The use of thromboelastography (TEG) and rotational thromboelastometry (ROTEM) in neonates: a systematic review.

Authors:  Georgios Ν Katsaras; Rozeta Sokou; Andreas G Tsantes; Daniele Piovani; Stefanos Bonovas; Aikaterini Konstantinidi; Georgios Ioakeimidis; Stauroula Parastatidou; Dimitra Gialamprinou; Athanasia Makrogianni; Georgios Mitsiakos; Argirios Ε Tsantes
Journal:  Eur J Pediatr       Date:  2021-06-16       Impact factor: 3.183

3.  Subcapsular Liver Hematoma-A Life-Threatening Condition in Preterm Neonates-A Case Series and Systematic Review of the Literature.

Authors:  Paraskevi Liakou; Anastasia Batsiou; Aikaterini Konstantinidi; Martha Theodoraki; Paschalia Taliaka Kopanou; Evangelia-Filothei Tavoulari; Andreas G Tsantes; Daniele Piovani; Stefanos Bonovas; Argirios E Tsantes; Nicoletta Iacovidou; Rozeta Sokou
Journal:  J Clin Med       Date:  2022-09-26       Impact factor: 4.964

4.  Rotational Thromboelastometry Findings Are Associated with Symptomatic Venous Thromboembolic Complications after Hip Fracture Surgery.

Authors:  Andreas G Tsantes; Dimitrios V Papadopoulos; Ioannis G Trikoupis; Konstantina A Tsante; Andreas F Mavrogenis; Panagiotis Koulouvaris; Daniele Piovani; Anastasios G Kriebardis; Argyri Gialeraki; Georgios K Nikolopoulos; Stefanos Bonovas; Panayiotis J Papagelopoulos; Argirios E Tsantes
Journal:  Clin Orthop Relat Res       Date:  2021-11-01       Impact factor: 4.755

5.  Reference Values of Thromboelastometry Parameters in Healthy Term Neonates Using NATEM in Cord Blood Samples.

Authors:  Alma Sulaj; Marina Tsaousi; Eleni Karapati; Abraham Pouliakis; Zoi Iliodromiti; Theodora Boutsikou; Serena Valsami; Nicoletta Iacovidou; Marianna Politou; Rozeta Sokou
Journal:  Children (Basel)       Date:  2022-01-02

Review 6.  The Non-Activated Thromboelastometry (NATEM) Assay's Application among Adults and Neonatal/Pediatric Population: A Systematic Review.

Authors:  Petroula Georgiadou; Rozeta Sokou; Andreas G Tsantes; Stavroula Parastatidou; Aikaterini Konstantinidi; Dimitra Houhoula; Styliani Kokoris; Nicoletta Iacovidou; Argirios E Tsantes
Journal:  Diagnostics (Basel)       Date:  2022-03-08
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.