Literature DB >> 32838461

Various Types of Medial Tibial Bone Resorption after Total Knee Arthroplasty Using a Thick Cobalt Chromium Tibial Baseplate.

Sang Jun Song1, Hyun Woo Lee1, Se Gu Kang1, Dae Kyung Bae2, Cheol Hee Park1.   

Abstract

Recent literature has implicated a thick cobalt chromium baseplate as a potential source of stress shielding and medial tibial bone resorption after total knee arthroplasty (TKA) in a Western population. The purpose was to calculate the incidence of various types and severity of medial tibial bone resorption utilizing a novel classification system after TKA with a thick cobalt chromium baseplate in Asian patients. Five hundred TKAs using Attune prostheses with mean follow-up of 3.4 years were evaluated, using the prospective radiographic data. The mean age was 71.3 years. The preoperative mechanical axis was varus, 11.2 degrees. The type and severity of medial tibial bone resorption were categorized as type U (resorption under the tibial baseplate up to 50% [U1] or beyond 50% [U2] of medial tibial tray width), C (resorption around the penetrated cement under the baseplate), and M (resorption on the medial tibial cortex without extension to the baseplate). Bone resorption of medial proximal tibia was observed in 96 knees (19.2%). Types U1 and U2 were seen in 46 and 28 knees, respectively. Type C was observed in 12 knees and type M in 10 knees. The type U resorption group had significantly more preoperative varus deformity (varus 12.9 vs. 10.9 degrees, p = 0.017). Medial tibial bone resorption after TKAs using a thick cobalt chromium baseplate is not uncommon and has various locations, types, and severities. The medial tibial bone resorption might be related to various causes, including stress shielding, thermal necrosis from cement in the bony hole, and bony devascularization. The type-U resorption has to be closely observed in patients with preoperative severe varus deformity. This is a Level IV study. Thieme. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2020        PMID: 32838461     DOI: 10.1055/s-0040-1715085

Source DB:  PubMed          Journal:  J Knee Surg        ISSN: 1538-8506            Impact factor:   2.757


  1 in total

1.  Stress shielding in total knee replacements: Comparative analysis between titanium and all-polyethylene bases at 10 years follow-up.

Authors:  Germán Garabano; Joaquín Rodriguez; Leonel Perez Alamino; Cesar Angel Pesciallo; Hernán Del Sel; Fernando Lopreite
Journal:  J Orthop       Date:  2022-09-16
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.