Literature DB >> 3283463

Composite graft replacement of the ascending aorta and aortic valve. Late follow-up with intra-arterial digital subtraction angiography.

M A Marvasti1, F B Parker, P A Randall, G A Witwer.   

Abstract

Between 1979 and 1986, 30 patients underwent replacement of the aortic valve and ascending aorta by a composite graft, with aortic wrapping of the graft. Thirteen patients had annuloaortic ectasia; six had DeBakey type I dissection (five acute, one chronic); three had DeBakey type II dissection (one acute, two chronic); three had left ventricular-aortic discontinuity caused by prosthetic valve endocarditis; three had sinus of Valsalva aneurysms after previous aortic valve procedures; and two had atherosclerotic aneurysms. Three patients died (10%). The mean duration of follow-up was 54 months. Fifteen patients consented to be restudied by intra-arterial digital subtraction angiography; studies were performed 6 to 58 months (mean 25 months) after composite graft replacement. Two patients had pseudoaneurysms at the right coronary anastomosis, which were repaired successfully. One patient showed persistent dissection beyond the distal aortic anastomosis; no reoperation has been done. One patient had pulmonary edema. Emergency study and reoperation showed disruption of the proximal aortic anastomosis and right coronary anastomosis. Anastomotic dehiscence after composite graft replacement is potentially lethal. Follow-up by means of intra-arterial digital subtraction angiography is simple and highly accurate. We suggest that dehiscences may occur early in the postoperative period and that restudy may be appropriate within a few months after operation.

Entities:  

Mesh:

Year:  1988        PMID: 3283463

Source DB:  PubMed          Journal:  J Thorac Cardiovasc Surg        ISSN: 0022-5223            Impact factor:   5.209


  6 in total

1.  Improving hemostasis during replacement of the ascending aorta and aortic valve with a composite graft.

Authors:  S Pratali; A Milano; R Codecasa; M De Carlo; G Borzoni; U Bortolotti
Journal:  Tex Heart Inst J       Date:  2000

2.  Successful surgical treatment of a pseudoaneurysm after composite graft replacement of the aortic valve and ascending aorta: report of two cases.

Authors:  C Yamashita; Y Tsuji; M Yoshimura; S Kozawa; M Okada
Journal:  Surg Today       Date:  1994       Impact factor: 2.549

3.  Sixteen-year experience with aortic root replacement. Results of 172 operations.

Authors:  N T Kouchoukos; T H Wareing; S F Murphy; J B Perrillo
Journal:  Ann Surg       Date:  1991-09       Impact factor: 12.969

4.  Superior vena cava syndrome in a patient with previous cardiac surgery: what else should we suspect?

Authors:  Panagiotis Dedeilias; Ioannis Nenekidis; Panagiotis Hountis; Christos Prokakis; Paraskevi Dolou; Efstratios Apostolakis; Efstratios N Koletsis
Journal:  Diagn Pathol       Date:  2010-06-25       Impact factor: 2.644

5.  New modification of modified bentall procedure (A single centre experience).

Authors:  Ghulam Hussain; Naseem Ahmad; Sohail Ahmad; Mirza Ahmad Raza Baig; Sara Zaheer; Aamir Furkan
Journal:  Pak J Med Sci       Date:  2015 Nov-Dec       Impact factor: 1.088

6.  Behcet's disease involved the root of aorta in the treatment with modified Bentall procedure: a case report.

Authors:  Zeyi Cheng; Zhefeng Kang; Yupeng Ji; Yingqiang Guo
Journal:  J Cardiothorac Surg       Date:  2020-01-29       Impact factor: 1.637

  6 in total