| Literature DB >> 32819451 |
Kensaku Sasayama1, Minoru Adachi2.
Abstract
OBJECTIVE: This study compared the measurements of total steps and moderate-to-vigorous physical activity (MVPA) between ActiGraph and the Lifecorder and Active Style Pro accelerometers in junior high school students.Entities:
Keywords: ActiGraph; Active style pro; Lifecorder; Moderate-to-vigorous physical activity; Total steps
Mesh:
Year: 2020 PMID: 32819451 PMCID: PMC7441544 DOI: 10.1186/s13104-020-05231-x
Source DB: PubMed Journal: BMC Res Notes ISSN: 1756-0500
ICCs for total steps and MVPA measured using AG and LC
| AG | LC | ICC | 95% CI | p values | |
|---|---|---|---|---|---|
| Total steps (steps) | 2176.6 (506.0) | 4994.2 (2588.4)* | −0.20 | −0.70–0.45 | 0.72 |
| MVPA (min) | 3.3 (4.2) | 11.0 (7.8)* | −0.19 | −0.70–0.46 | 0.72 |
MVPA moderate-to-vigorous physical activity, AG ActiGraph GT9X , ink, LC Lifecorder EX, ICC intraclass correlation coefficient, CI confidence Interval
*p < 0.05 for differences between AG and LC
ICCs for total steps and MVPA measured using AG and ASP
| AG | ASP | ICC | 95% CI | p values | |
|---|---|---|---|---|---|
| Total steps (steps) | 2241.4 (896.8) | 2597.9 (1266.7) | 0.74 | 0.28–0.93 | < 0.01 |
| MVPA (minutes) | 2.9 (3.4) | 13.8 (9.7)* | −0.07 | −0.62–0.55 | 0.58 |
MVPA moderate-to-vigorous physical activity, AG ActiGraph GT9X Link, ASP Active Style Pro HJA-750C, ICC intraclass correlation coefficient, CI confidence interval
*p < 0.05 for differences between AG and ASP
Fig. 1Bland–Altman plots for AG, LC, and ASP. a AG and LC mean total steps, b AG and LC mean MVPA, c AG and ASP mean total steps, d AG and ASP mean MVPA