Literature DB >> 32805509

A plasmonic fiberoptic absorbance biosensor for mannose-capped lipoarabinomannan based tuberculosis diagnosis.

Divagar M1, Ramakrishna Bandaru2, Vani Janakiraman3, V V R Sai4.   

Abstract

Tuberculosis (TB) is a resurgent infectious disease affecting a large number of people in the developing countries. An on-site, affordable diagnostic screening at an early-stage for an immediate anti-TB treatment is known to tremendously minimize the high mortality rates. Lipoarabinomannan (LAM), a surface glycolipid, has been identified as a potential TB biomarker present in urine at ultra-low concentrations of a few fg/mL. Here, we report a plasmonic fiber optic absorbance biosensor (P-FAB) strategy for mannosylated LAM (Man-LAM or Mtb LAM) detection down to attomolar concentrations. It involves a plasmonic sandwich immunoassay on a U-bent fiber optic probe with gold plasmonic (AuNP) labels functionalized with anti-Mtb LAM immunoglobulin M (IgM) and anti-Mtb LAM IgG respectively. The Mtb LAM is quantified in terms of absorption of light passing through the fiber probe using a green LED and a photodetector. The choice of fiber optic probes (fused silica versus polymer), the optimum size (20, 40, 60 and 80 nm) and concentration (2 × , 10 × , and 20 × ) of AuNP labels were investigated to obtain high sensitivity and lower limits of analyte detection (LoD). P-FAB with a simple LED-photodetector pair, 200 μm fused silica U-bent fiber probe and 60 nm (20 × ) AuNP labels gave LoDs down to 1 fg/mL and 10 fg/mL in the buffer and synthetic urine respectively. Moreover, the anti-Mtb LAM IgM bound sensor probes and the AuNP reagent stored at 4 °C were stable up to 45 days. P-FAB based Mtb LAM sensor demonstrates its potential for an on-site TB diagnosis.
Copyright © 2020 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Attomolar analyte detection; Mannosylated lipoarabinomannan; Plasmonic fiber-optic absorbance biosensor; Sandwich immunoassay; Tuberculosis

Mesh:

Substances:

Year:  2020        PMID: 32805509     DOI: 10.1016/j.bios.2020.112488

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  2 in total

1.  Plasmonic Fiberoptic Absorbance Biosensor (P-FAB) for Rapid Detection of SARS-CoV-2 Nucleocapsid Protein.

Authors:  M Divagar; R Gayathri; Rahiel Rasool; J Kuzhandai Shamlee; Himanshu Bhatia; Jitendra Satija; V V R Sai
Journal:  IEEE Sens J       Date:  2021-08-24       Impact factor: 3.301

Review 2.  Lipoarabinomannan as a Point-of-Care Assay for Diagnosis of Tuberculosis: How Far Are We to Use It?

Authors:  Julio Flores; Juan Carlos Cancino; Leslie Chavez-Galan
Journal:  Front Microbiol       Date:  2021-04-15       Impact factor: 5.640

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.