| Literature DB >> 32802769 |
Nada Jaafar1, Hala Ragab2, Ahmed Abedrahman3, Essam Osman4.
Abstract
AIM ANDEntities:
Keywords: Canary system; DIAGNOdent pen; International Caries Detection and Assessment System; fissure sealants; non-cavitated occlusal caries
Year: 2020 PMID: 32802769 PMCID: PMC7402262 DOI: 10.4103/jispcd.JISPCD_480_19
Source DB: PubMed Journal: J Int Soc Prev Community Dent ISSN: 2231-0762
Descriptive statistics and results of McNemar test and Cochran Q test for comparison between caries scores by time with each modality
| Modality | Baseline | 3 months | 6 months | |
|---|---|---|---|---|
| Two-digit ICDAs | 0.296 | |||
| Code 20 (sealant, full, and sound) | - | 77 (85.6) | 70 (77.8) | |
| Code 21 (sealant, full, and first visual change in enamel) | 0 (0) | 1 (1.1) | ||
| Code 11 (sealant, partial, and first visual change in enamel) | 1 (1.1) | 4 (4.4) | ||
| Code 12 (sealant, partial, distinct visual change in enamel) | 10 (11.1) | 10 (11.1) | ||
| Code 13 (sealant, partial, and localized enamel breakdown) | 2 (2.2) | 5 (5.6) | ||
| CS | <0.001* | |||
| Sound (score 0–20) | 5 (5.6)b | 29 (32.2)a | 38 (42.2)a | |
| Carious (score ≥21) | 85 (94.4) | 61 (67.8%) | 52 (57.8) | |
| DP | 0.015* | |||
| Sound (score 0–13) | 3 (3.3)b | 6 (6.7)b | 12 (13.3)a | |
| Carious (score ≥14) | 87 (96.7) | 84 (93.3) | 78 (86.7) |
CS = Canary System, DP = DIAGNOdent pen
*Significant at P ≤ 0.05, different superscripts in the same row are statistically significantly different
Sensitivity, specificity, predictive values, diagnostic accuracy, area under the receiver operating characteristic curve (AUC), and 95% confidence interval of the AUC for caries detection by the Canary System and DIAGNOdent pen after 3 months
| Diagnosis | Modality | Sensitivity % | Specificity % | +PV % | −PV % | Diagnostic accuracy % | AUC | 95% Confidence interval |
|---|---|---|---|---|---|---|---|---|
| Code 20 vs. all other codes (any change in E) | CS | 69.2 | 32.5 | 14.8 | 86.2 | 38 | 0.508 | 0.401–0.615 |
| DP | 7.7 | 93.5 | 16.7 | 85.7 | 81.9 | 0.506 | 0.398–0.613 | |
| Code 20 vs. Code 12 (E distinct visual change) | CS | 100 | 38.4 | 18.2 | 100 | 45.8 | 0.692 | 0.581–0.789 |
| DP | 100 | 6.9 | 12.8 | 100 | 18.1 | 0.534 | 0.421–0.645 |
CS = Canary System, DP = DIAGNOdent pen, +PV = positive predictive value, −PV = negative predictive value
Sensitivity, specificity, predictive values, diagnostic accuracy, area under the receiver operating characteristic curve (AUC), and 95% confidence interval (95% CI) of the AUC for caries detection by Canary System and DIAGNOdent pen after 6 months
| Diagnosis | Modality | Sensitivity % | Specificity % | +PV % | −PV % | Diagnostic accuracy % | AUC | 95% Confidence interval |
|---|---|---|---|---|---|---|---|---|
| Code 20 vs. all other codes (any change in E) | CS | 60 | 42.9 | 23.1 | 78.9 | 46.7 | 0.514 | 0.407–0.621 |
| DP | 95 | 15.7 | 24.4 | 91.7 | 33.4 | 0.554 | 0.445–0.658 | |
| Code 20 vs. Code 12 (E distinct visual change) | CS | 50 | 57.1 | 14.3 | 88.9 | 56.2 | 0.536 | 0.421–0.648 |
| DP | 90 | 15.7 | 13.2 | 91.7 | 25 | 0.529 | 0.414–0.641 | |
| Code 20 vs. Code 13 (localized E breakdown) | CS | 80 | 42.9 | 9.1 | 96.8 | 45.4 | 0.614 | 0.495–0.724 |
| DP | 100 | 15.7 | 7.8 | 100 | 21.3 | 0.579 | 0.459–0.692 |
CS = Canary System, DP = DIAGNOdent pen, +PV = positive predictive value, −PV = negative predictive value
Figure 1Receiver operating characteristic curves of the two modalities for caries detection (Code 20 vs. all other codes) after 3 months
Figure 4Receiver operating characteristic curves of the two modalities for caries detection (Code 20 vs. Code 13) after 6 months