Literature DB >> 32800315

Stability of internal versus external fixation in osteoporotic pelvic fractures - a biomechanical analysis.

J Hack1, Y Kranz2, T Knauf2, M Bäumlein2, D Malcherczyk3, S Ruchholtz2, L Oberkircher2.   

Abstract

INTRODUCTION: Osteoporosis-related fragility fractures of the pelvic ring (FFP) differ fundamentally from pelvic fractures in younger patients. However, very little is known about biomechanical stability of different osteosynthesis procedures addressing the anterior pelvic ring in these fractures. The aim of this study was to compare standard external fixation with internal fixation using a novel screw-and-rod system in osteoporotic fractures of the pelvic ring in terms of stiffness, plastic deformation and maximum load under cyclic loading in a human cadaveric model.
MATERIALS AND METHODS: A total of 18 embalmed osteoporotic cadaver pelvis specimens were randomized based on the T-score into a group for external fixation and a group for internal fixation. FFP type-IIB fractures were created. In addition to the external or internal fixator, a cement-augmented sacroiliac screw was implanted. Afterwards, axial cyclic loading was performed in a testing setup simulating one-leg stand.
RESULTS: Mean plastic deformation and stiffness both were significantly better in the internal fixation group than in the external fixation group (plastic deformation: 0.37 mm (SD: 0.23) versus 0.71 mm (SD: 0.26), p = 0.011; stiffness: 43.69 N/mm (SD: 18.39) versus 26.52 N/mm (SD: 9.76), p = 0.029). Maximum load did not differ significantly between internal fixator (506.3 N; SD: 129.4) and external fixator (461.1 N; SD: 147.4) (p = 0.515).
CONCLUSIONS: Submuscular internal fixation might be an interesting alternative to external fixation in clinical practice because of better biomechanical properties as well as several advantages in clinical use.
Copyright © 2020. Published by Elsevier Ltd.

Entities:  

Keywords:  External fixator; Fragility fracture of the pelvis; Internal fixator; Osteoporosis; Pelvic ring injury

Mesh:

Year:  2020        PMID: 32800315     DOI: 10.1016/j.injury.2020.08.017

Source DB:  PubMed          Journal:  Injury        ISSN: 0020-1383            Impact factor:   2.586


  3 in total

1.  Minimally invasive internal fixation for unstable pelvic ring fractures: a retrospective study of 27 cases.

Authors:  Shuang Wu; Jialei Chen; Yun Yang; Wei Chen; Rong Luo; Yue Fang
Journal:  J Orthop Surg Res       Date:  2021-05-31       Impact factor: 2.359

2.  A Novel Instant 3-Dimensional Printing System for Postoperative Fracture Patients: A Comparative Cohort Study.

Authors:  Lang Chen; Yuan Xiong; Bobin Mi; Chenchen Yan; Xudong Xie; Zexi He; Wu Zhou; Guohui Liu
Journal:  Med Sci Monit       Date:  2021-01-01

3.  Is cement-augmented sacroiliac screw fixation with partially threaded screws superior to that with fully threaded screws concerning compression and pull-out force in fragility fractures of the sacrum? - a biomechanical analysis.

Authors:  Juliana Hack; Maiwand Safi; Martin Bäumlein; Julia Lenz; Christopher Bliemel; Steffen Ruchholtz; Ludwig Oberkircher
Journal:  BMC Musculoskelet Disord       Date:  2021-12-10       Impact factor: 2.362

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.