| Literature DB >> 32798323 |
Huw A S Jones1, Rami J Salib1, Philip G Harries1.
Abstract
OBJECTIVES: The presence of high SARS-Cov-2 viral loads in the upper airway, including the potential for aerosolized transmission of viral particles, has generated significant concern amongst otolaryngologists worldwide, particularly those performing endoscopic sinus surgery (ESS). We evaluated a simple negative-pressure mask technique to reduce viral exposure.Entities:
Keywords: COVID-19 virus; endoscopic sinus surgery; mask; negative pressure; rhinology; severe acute respiratory syndrome coronavirus 2
Mesh:
Substances:
Year: 2020 PMID: 32798323 PMCID: PMC7460946 DOI: 10.1002/lary.29065
Source DB: PubMed Journal: Laryngoscope ISSN: 0023-852X Impact factor: 2.970
Fig. 1Endoscopy mask.
White Pixel Count for the Final Subtraction Image in Each Respiratory Nuclei Scenario.
| Scenario | White Pixel Count |
|---|---|
| 1 No mask | 12,020,889 |
| 2 Mask fitted, no suction | 9,736,099 |
| 3 Mask fitted, suction applied | 216,316 |
| 4 Mask fitted, suction, instrument valve removed | 153,636 |
| 5 Mask fitted, suction, instrument valve removed, with endoscope | 214,731 |
Fig. 2(A) Reference image for Scenario 1, (B) (A) with threshold filter applied, (C) stacked images throughout scenario 1, (D) (C) with threshold filter applied. Subtracting (B) from (D) results in image (A) in Figure 3.
Fig. 3Subtraction images for (A) Scenario 1, (B) Scenario 2, (C) Scenario 3, (D) Scenario 4, and (E) Scenario 5.
Fig. 4(A) Fluorescein test image under UV light, (B) fluorescein visible in microdebrider suction tubing only, (C) gross contamination within mask after external drill activation.
Results of the Respiratory Droplet Model.
| Scenario | Procedure | Mask | Duration | Droplet Spread | Maximum Distance |
|---|---|---|---|---|---|
| 1 | Powered microdebrider ESS | No | 4 min | No | — |
| Powered microdebrider ESS | Yes | 4 min | No | — | |
| 2 | Powered drilling of frontal recess & beak | No | 4 min | Yes | 10 cm |
| Powered drilling of frontal recess & beak | Yes | 4 min | No | — | |
| 3 | External drill activation with negative pressure | Yes | 20 sec | Yes | Confined within mask, nil external |
| External drill activation without negative pressure | Yes | 20 sec | Yes | Confined within mask, nil external |