Literature DB >> 32790882

Planning dosimetry for 90 Y radioembolization with glass microspheres: Evaluating the fidelity of 99m Tc-MAA and partition model predictions.

M Allan Thomas1, Armeen Mahvash2, Mohamed Abdelsalam2, Ahmed O Kaseb3, S Cheenu Kappadath1.   

Abstract

PURPOSE: 99m Tc-MAA-SPECT/CT may be used in 90 Y-glass microsphere radioembolization treatment planning to assess perfused liver volumes and absorbed dose distributions. The partition model (PM) offers a more detailed planning dosimetry option beyond the single-compartment model more traditionally used in 90 Y radioembolization. As 90 Y radioembolization treatments shift toward activities and doses that aim to achieve tumor control, accurate and reliable treatment planning dosimetry for both tumors and normal liver (NL) becomes more critical. In this work, we explore the accuracy and precision of 90 Y dosimetry predictions from pretherapy 99m Tc-MAA and PM.
METHODS: Both PM and voxel dosimetry models were used to calculate tumor and NL mean doses using both planning 99m Tc-MAA and verification 90 Y-SPECT/CT in this retrospective analysis of hepatocellular carcinoma cases treated with glass microspheres (NCT01900002, n = 32). Linear regression models were developed at first access, and then later correct, the estimates by (a) 99m Tc-MAA for 90 Y voxel dosimetry and (b) 99m Tc-MAA PM for voxel dosimetry, separately for both tumors and NL. Bland-Altman analysis was then used to evaluate the accuracy and precision of the regression model predictions with the mean bias and 95% prediction intervals (PI, ±1.96σ). Two categories of cases were stratified (catheter matched vs catheter unmatched) by establishing the level of 99m Tc-MAA and 90 Y catheter position alignment. Only catheter-matched cases were included in the 99m Tc-MAA vs 90 Y voxel dosimetry comparison, while all cases were used to compare dosimetry models (PM vs voxel).
RESULTS: Half (16/32) of cases were deemed catheter matched. 99m Tc-MAA could reliably predict NL doses in catheter-matched cases after application of the linear model, with mean bias (PI) of -1% (±31%). PM was equivalent to voxel dosimetry for NL doses with mean bias (PI) of 0% (±1%). Even among catheter-matched cases, 99m Tc-MAA planning for 90 Y tumor voxel doses was poor, overestimating dose by an average of nearly 40%. Upon application of the linear model, 99m Tc-MAA predictions for 90 Y tumor voxel dose were only minimally biased (-4%) but possessed very large PI (±104%). PM predictions for tumor voxel dose using the linear model also showed small bias (-6%) but maintained similarly high PI of ±90%. Cases with tumors representing a large majority (>80%) of the total tumor volume demonstrated the best scenarios for 99m Tc-MAA and PM tumor dose predictions, with mean biases (PI) of -3% (±53%) and -4% (±21%), respectively.
CONCLUSION: The unconditional use of 99m Tc-MAA to predict 90 Y dosimetry across all cases is not recommended due to: (a) demonstrated the risk of unmatched catheter positions between procedures, and (b) large bias and uncertainty in 99m Tc-MAA predictions in cases with matched catheter locations. However, NL voxel dose predictions with 99m Tc-MAA are clinically viable and either PM or voxel dosimetry can be used to produce equivalent predictions. Both 99m Tc-MAA and PM can provide tumor dose predictions with potential clinical utility, but only in catheter-matched cases and with tumors comprising a clear majority (>80%) of the total tumor volume. These findings stratify the predictive fidelity of 99m Tc-MAA- and PM-based treatment planning for 90 Y dosimetry in improving treatment outcomes.
© 2020 American Association of Physicists in Medicine.

Entities:  

Keywords:  90Y; MAA; SIRT; dosimetry; partition; radioembolization

Mesh:

Substances:

Year:  2020        PMID: 32790882     DOI: 10.1002/mp.14452

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  4 in total

1.  Clinical, dosimetric, and reporting considerations for Y-90 glass microspheres in hepatocellular carcinoma: updated 2022 recommendations from an international multidisciplinary working group.

Authors:  Riad Salem; Siddharth A Padia; Marnix Lam; Carlo Chiesa; Paul Haste; Bruno Sangro; Beau Toskich; Kirk Fowers; Joseph M Herman; S Cheenu Kappadath; Thomas Leung; Daniel Y Sze; Edward Kim; Etienne Garin
Journal:  Eur J Nucl Med Mol Imaging       Date:  2022-09-17       Impact factor: 10.057

Review 2.  Standard Radiation Dosimetry Models: What Interventional Radiologists Need to Know.

Authors:  Linzi Arndt Webster; Alexander Villalobos; Bill S Majdalany; Zachary L Bercu; Ripal T Gandhi; Nima Kokabi
Journal:  Semin Intervent Radiol       Date:  2021-10-07       Impact factor: 1.780

3.  A Prospective Phase II Study of Safety and Efficacy of Sorafenib Followed by 90Y Glass Microspheres for Patients with Advanced or Metastatic Hepatocellular Carcinoma.

Authors:  Ahmed Omar Kaseb; S Cheenu Kappadath; Sunyoung S Lee; Kanwal Pratap Raghav; Yehia I Mohamed; Lianchun Xiao; Jeffrey S Morris; Chimela Ohaji; Rony Avritscher; Bruno C Odisio; Joshua Kuban; Mohamed E Abdelsalam; Beth Chasen; Khaled M Elsayes; Mohamed Elbanan; Robert A Wolff; James C Yao; Armeen Mahvash
Journal:  J Hepatocell Carcinoma       Date:  2021-09-09

4.  Y-90 SIRT: evaluation of TCP variation across dosimetric models.

Authors:  Benjamin J Van; Yuni K Dewaraja; Mamadou L Sangogo; Justin K Mikell
Journal:  EJNMMI Phys       Date:  2021-06-10
  4 in total