Literature DB >> 32789549

Management of peri-implantitis using a diode laser (810 nm) vs conventional treatment: a systematic review.

Hebatallah Mattar1,2, Mohamed Bahgat3, Amir Ezzat4, Bassant Bahaa El-Din3, Khaled Keraa5, Iman El Taftazany6.   

Abstract

The purpose of this study was to systematically assess clinical studies on the effect of using a diode laser in the treatment of peri-implantitis. Study question was "In patients with peri-implantitis around functional dental implants, can treatment by a diode Laser (810 nm) versus conventional treatment be effective in reducing the probing depth?". The study included only randomized controlled clinical trials that involved patients with peri-implantitis. Included articles evaluated a diode laser (810 nm) used as monotherapy or as adjuvant therapy in the non-surgical treatment while their control group received conventional methods of treatment for peri-implantitis. Studies that involved other types of laser treatment options, surgical therapy, photodynamic therapy, case series, or case reports were excluded. Three electronic databases were searched for published articles from 2010 to 2018: PubMed/Medline, Cochrane, and Web of Science. The references were manually hand searched for relevant articles. The search initially identified 44 studies, which were filtered to yield a total of 3 eligible studies. All included studies compared laser treatment by a diode laser (810 nm) to conventional therapy by mechanical debridement for a follow-up period ranging from 6 months to 1 year, and risk of bias was assessed for each of the three included studies. A qualitative analysis of the three studies was conducted. This systematic review could not support the usage of a diode laser in the treatment of peri-implantitis. To confirm this assumption, more clinical trials with long-term follow-up periods are recommended.

Entities:  

Keywords:  Dental diodes; Dental implants; Dental scaling; Diode 810 nm; Laser root planning; Laser scaling; Lasers; Peri-implantitis; Scaling and root planning

Year:  2020        PMID: 32789549     DOI: 10.1007/s10103-020-03108-w

Source DB:  PubMed          Journal:  Lasers Med Sci        ISSN: 0268-8921            Impact factor:   3.161


  3 in total

1.  Temperature changes at the implant-bone interface during simulated surface decontamination with an Er:YAG laser.

Authors:  Matthias Kreisler; Haitham Al Haj; Bernd d'Hoedt
Journal:  Int J Prosthodont       Date:  2002 Nov-Dec       Impact factor: 1.681

2.  Treatment of peri-implantitis: Meta-analysis of findings in a systematic literature review and novel protocol proposal.

Authors:  Ausra Ramanauskaite; Povilas Daugela; Gintaras Juodzbalys
Journal:  Quintessence Int       Date:  2016       Impact factor: 1.677

3.  Clinical outcome of a nonsurgical and surgical treatment protocol in different types of peri-implantitis: a case series.

Authors:  René Thierbach; Thomas Eger
Journal:  Quintessence Int       Date:  2013-02       Impact factor: 1.677

  3 in total
  2 in total

1.  Assessment of implant surface and instrument insert changes due to instrumentation with different tips for ultrasonic-driven debridement.

Authors:  Philipp Sahrmann; Sophie Winkler; Andrea Gubler; Thomas Attin
Journal:  BMC Oral Health       Date:  2021-01-07       Impact factor: 2.757

2.  In-vitro assessment of the efficiency of cold atmospheric plasma on decontamination of titanium dental implants.

Authors:  Christian Flörke; Josephine Janning; Cedric Hinrichs; Eleonore Behrens; Kim Rouven Liedtke; Sinan Sen; David Christofzik; Jörg Wiltfang; Aydin Gülses
Journal:  Int J Implant Dent       Date:  2022-03-11
  2 in total