| Literature DB >> 32779964 |
Harish Dharmarajan1, Monika E Freiser1, Edward Sim2, Devi Sai Sri Kavya Boorgu2, Timothy E Corcoran3, Eric W Wang1, Paul A Gardner4, Carl H Snyderman1.
Abstract
OBJECTIVE: To define the aerosol and droplet risks associated with endonasal drilling and to identify mitigation strategies. STUDYEntities:
Keywords: COVID-19; aerosol; droplet; endonasal; prevention; safety; skull base
Year: 2020 PMID: 32779964 PMCID: PMC7424614 DOI: 10.1177/0194599820949802
Source DB: PubMed Journal: Otolaryngol Head Neck Surg ISSN: 0194-5998 Impact factor: 3.497
Figure 1.Field contamination setup. (A, B) Fluorescent 3-dimensional (3D) model with and without face covering. (C) The 3D model or cadaveric specimen was placed on top of a tarp with 6-inch distances marked. After each 2-minute trial, the tarp was examined for debris. (D) 3D model demonstrating drilling conditions.
Figure 2.Impactor survey setup. (A) Impactor setup with vacuum generator (black arrow) and flow meter (white arrow). (B) Opened view of Next Generation Impactor (NGI) with aluminum foils in collection chambers. Experimental setup demonstrating nebulizer conditions with 3-dimensional (3D) model (C) and cadaver head (D) with the impactor inlet just inferior and anterior to the nostrils. Experimental setup demonstrating drilling conditions with 3D model (E) and cadaver head (F).
Figure 3.Representative images of filter foil results from impactor trials. Photographs of removable foil pieces that lined the cascade impactor capture chambers illuminated under UV light for nebulized vitamin B2 trial (positive control; A), cadaver coarse diamond drilling with vitamin B2 irrigation without suction (B), cadaver coarse diamond drilling with vitamin B2 irrigation and suction use (C), 3-dimensional (3D) model cutting burr drilling with nebulized vitamin B2 without suction (D), and 3D model coarse diamond burr drilling with nebulized vitamin B2 without suction (E). Particles filtered based on average aerodynamic diameter into 8 impactor stages are displayed: (1) 14.1 µm, (2) 8.61 µm, (3) 5.39 µm, (4) 3.30 µm, (5) 2.08 µm, (6) 1.36 µm, (7) 0.98 µm, and (8) <0.98 µm.
Figure 4.Field contamination results. Representative grids and personal protective equipment (PPE) displaying field contamination present on tarp and provider PPE (gown and palmar and dorsal surfaces of gloves), respectively, following each trial. Each grid square represents 6-inch units with the model head oriented on the center of the left border of the grid (A). This scale and orientation were kept consistent across all images. Coarse diamond burr without suction (A) and cutting burr without suction (B) on fluorescent 3-dimensional model. Cutting burr drilling Draf III (C), cutting burr drilling clivus (D), and coarse diamond burr drilling Draf III (E) on cadaver head. All cadaver trials were with suction at the discretion of the surgeon.
Three-Dimensional Printed Sinonasal Model Trials.
| Trial | Particle Size (µm): D50 at 15 L/min | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Drill | Suction | B2 Tracer | 14.1 | 8.61 | 5.39 | 3.30 | 2.08 | 1.36 | 0.98 | <0.98 | |
| NA | NA | Nebulized B2 | – | – |
|
|
|
|
|
| |
| NA | Flexible suction[ | Nebulized B2 | — | — | — | — | — | — | — | — | |
| NA | NA | Nebulized Saline | — | — | — |
|
|
|
|
| |
| Coarse burr | NA | Nebulized B2 |
|
|
|
|
|
|
|
| |
| Cutting burr | NA | Nebulized B2 |
|
|
|
|
|
|
|
| |
| Cutting burr | Flexible suction[ | Nebulized B2 | — | — | — | — | — | — | — | — | |
Abbreviations: NA, not applicable; *, presence of blue fluorescent bone dust; **, increased presence of blue fluorescent bone dust; +, presence of particle aggregates; –, no particles present at the specific impactor stage.
Flexible suction was parked approximately 6 cm away from nasal aperture.
Cadaver Trials and Suction Mitigation.
| Trial | Particle Size (µm): D50 at 15 L/min | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Drill | Suction | B2 Tracer | 14.1 | 8.61 | 5.39 | 3.30 | 2.08 | 1.36 | 0.98 | <0.98 |
| NA | NA | Nebulized B2 | — | — |
|
|
|
|
|
|
| NA | Flexible suction in nasopharynx | Nebulized B2 | — | — | — | — | — | — | — | — |
| NA | Flexible suction at columella | Nebulized B2 | — | — | — | — | — | — | — | — |
| Coarse diamond | NA | B2 irrigation | — | — | — |
|
|
|
|
|
| Coarse diamond | Flexible suction | B2 irrigation | — | — | — | — | — | — | — | — |
Abbreviations: NA, not applicable; +, presence of particle aggregates; –, no particles present at the specific impactor stage.
Cadaver Trials and Mitigation With Nasal Aperture Reduction.
| Trial | Particle Size (µm): D50 at 15 L/min | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Drill | SPIWay | Suction | B2 Tracer | 14.1 | 8.61 | 5.39 | 3.30 | 2.08 | 1.36 | 0.98 | <0.98 |
| Coarse diamond | NA | NA | B2 irrigation | — | — | — |
|
|
|
|
|
| Coarse diamond | Bilateral | NA | B2 irrigation | — | — | — |
|
|
|
|
|
| Coarse diamond | Bilateral with rubber band | NA | B2 irrigation | — | — | — |
|
|
|
|
|
| Coarse diamond | Bilateral | Flexible suction | B2 irrigation | — | — | — | — | — | — | — | — |
| NA | NA | NA | Nebulized B2 | — | — |
|
|
|
|
|
|
| NA | Bilateral | NA | Nebulized B2 | — | — |
|
|
|
|
|
|
| Drill on right (inactive); endoscope on left | Bilateral with bunny rubber bands | Inactive rigid suction on left | Nebulized B2 | — | — |
|
|
|
|
|
|
| NA | Bilateral | Flexible suction | Nebulized B2 | — | — | — | — | — | — | — | — |
Abbreviations: NA, not applicable; +, presence of particle aggregates; –, no particles present at the specific impactor stage.