| Literature DB >> 32778119 |
Yiyong Wu1,2, Peihong Deng3, Yaling Tian1,2, Jinxia Feng1, Jingyun Xiao1, Junhua Li2, Jun Liu1, Guangli Li1, Quanguo He4,5.
Abstract
A method with high sensitivity, good accuracy and fast response is of ever increasing importance for the simultaneous detection of AA,Entities:
Keywords: Ascorbic acid; Dopamine; Electrochemical sensor; Polyvinylpyrrolidone; Simultaneous determination; Uric acid
Mesh:
Substances:
Year: 2020 PMID: 32778119 PMCID: PMC7419206 DOI: 10.1186/s12951-020-00672-9
Source DB: PubMed Journal: J Nanobiotechnology ISSN: 1477-3155 Impact factor: 10.435
Scheme 1Diagram for the preparation of PVP/GCE, GR/GCE and PVP-GR/GCE and the electrochemical behaviors of AA, DA and UA
Fig. 1SEM images of GR (a) and PVP-GR (b). Accelerating voltage: 20 kV
Fig. 2EDS spectrum (a) and typical SEM image (insert of A) of PVP- GR nanocomposite together with the corresponding element mapping images of C (b), N (c) and O (d)
Fig. 3CVs of different electrodes: a GCE, b PVP/GCE, c GR/GCE and d PVP-GR/GCE. Solution: 1.0 mM K3[Fe(CN)6] in 1.0 M KCl; Scan rate: 0.1 V s−1
Fig. 4CVs obtained on the PVP-GR/GCE in 0.1 M PBS (pH 6.0) in the absence (black) and presence of 1.0 mM AA (red), 20 μM DA (green), 50 μM UA (blue) and a mixture solution containing 1.0 mM AA, 20 μM DA and 50 μM UA (brown), respectively. Scan rate: 100 mV s−1
Fig. 5Second-order derivative linear scan voltammograms (SDLSVs) obtained at GCE (a), PVP/GCE (b), GR/GCE (c) and PVP-GR/GCE (d) in 0.1 M phosphate buffer solution (pH 6.0) containing 1.0 mM AA, 20 μM DA and 50 μM UA. (0.0 V for the accumulation potential; 60 s for the accumulation time; 0.1 V s−1 for the scan rate)
Fig. 6Influences of pH value on the oxidation peak potential (a) and oxidation peak current (b) of 1.0 mM AA, 20 μM DA and 50 μM UA obtained at PVP-GR/GCE, respectively. The scan rate was 100 mV s−1. The concentration of PBS was 0.1 M (pH 6.0). Error bars represent SD, n = 3
Fig. 7CVs obtained on PVP-GR/GCE in phosphate buffer solution PBS (0.1 M, pH 6.0) in the presences of 1.0 mM AA (a), 20 μM DA (b) and 50 μM UA (c) respectively by different scan rates (20, 40, 60, 80, 100, 120, 140, 160, 180, 200 mV s−1)
Fig. 8The influence of accumulation potential (a) and time (b) on the oxidation currents of 1.0 mM AA, 20 μM DA and 50 μM UA. Error bars represent SD, n = 3
Fig. 9A SDLSVs of AA at the PVP-GR/GCE in the presence of 20 μM DA and 50 μM UA. a AA concentrations (from a to f): 100, 200, 400, 600, 80, 1000 μM; b AA concentrations (from g to n): 4, 6, 8, 10, 20, 40, 60, 80 μM. c Plots of peak height vs. AA concentration in the range of 4–1000 μM. B SDLSVs of DA at the PVP-GR/GCE in the presence of 1.0 mM AA and 50 μM UA. a DA concentrations (from a to o): 0.2, 0.4, 0.6, 0.8, 1.0, 2.0, 4.0, 6.0, 8.0, 10, 20, 40, 60, 80 and 100 μM; b DA concentrations (from p to u): 0.02, 0.04, 0.06, 0.08, 0.1, 0.2 μM; c Plots of peak height vs. DA concentration in the range of 0.2–100 μM and d in the range of 0.02–0.2 μM. C SDLSVs of UA at the PVP-GR/GCE in the presence of 1.0 mM AA and 20 μM DA. a UA concentrations (from a to k): 1.0, 2.0, 4.0, 6.0, 8.0, 10, 20, 40, 60, 80, and 100 μM; b UA concentrations (from l to s): 0.04, 0.06, 0.08, 0.1, 0.2, 0.4, 0.6, 0.8 μM; c Plots of peak height vs. UA concentration in the range of 1.0–100 μM and d in the range of 0.04–1.0 μM. 0.1 M PBS (pH 6.0) for the supporting electrolyte, 0.0 V for the accumulation potential, 60 s for the accumulation time, 0.1 V s−1 for the scan rate. Error bars represent SD, n = 3
Comparison of analytical performance of PVP-GR/GCE with other modified electrodes in the literature
| Modified electrode | Technique | Linear range/μM | Detection limit/μM | Reference | ||||
|---|---|---|---|---|---|---|---|---|
| AA | DA | UA | AA | DA | UA | |||
| Pd/CNF-CPEa | DPVi | 50–4000 | 0.5–160 | 2.0–200 | 15.0 | 0.20 | 0.70 | [ |
| PGE-DAb | DPV | 25–500 | 1.0–20 | 2.5–30 | 13.0 | 0.11 | 1.40 | [ |
| MCNT/CCEc | DPV | 15–800 | 0.5–100 | 0.55–90 | 7.71 | 0.31 | 0.42 | [ |
| PrGO/MnO2/CCEd | DPV | 1–800 | 0.03–45 | 0.3–80 | 1.00 | 0.02 | 0.05 | [ |
| AuNPs-β-CD–GR/GCEe | SWVj | 30–2000 | 0.50–150 | 0.5–60 | 10 | 0.15 | 0.21 | [ |
| SGNF/IL/CS/GCEf | DPV | 30–350 | 0.05–240 | 0.12–260 | 14.8 | 0.04 | 0.10 | [ |
| GR-Pt/GCEg | Amperometry | 0.15–34.4 | 0.03–8.13 | 0.05–11.85 | 0.15 | 0.03 | 0.05 | [ |
| Trp-GR/GCEh | DPV | 200–12900 | 0.5–110 | 10–1000 | 10.09 | 0.29 | 1.24 | [ |
| PVP-GR/GCE | SDLSV | 4.0–1000 | 0.02–0.2; 0.2–100 | 0.04–1.0; 1.0–100 | 0.8 | 0.002 | 0.02 | This work |
aPalladium nanoparticle-loaded carbon nanofibers modified carbon paste electrode
bPyrolytic graphite electrode modified into dopamine solution
cMWCNT modified carbon-ceramic electrode
dPoly(3,4-ethylenedioxythiophene)/reduced graphene oxide/manganese dioxide modified glassy carbon electrode
eGold nanoparticles-β-cyclodextrin-graphene-modified electrode
fStacked graphene platelet nanofibers/ionic liquids/chitosan modified glassy carbon electrode
gGraphene/size-selected Pt nanocomposites modified glassy carbon electrode
hTryptophan functionalized graphene modified glassy carbon electrode
iDifferential pulse voltammetry
jSquare wave voltammetry
Determination of AA DA, and UA in human urine samples (n = 4)
| Samplesa | Detected a/µM | Added/µM | Foundb/µM | Recovery/ % | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| AA | DA | UA | AA | DA | UA | AA | DA | UA | AA | DA | UA | |
| Urine 1 | – | – | 2.57 (± 0.09) | 10.0 | 10.0 | 2.0 | 10.25 (± 0.42) | 10.18 (± 0.37) | 4.63 (± 0.19) | 102.5 | 101.8 | 103.0 |
| Urine 2 | – | – | 1.58 (± 0.08) | 50.0 | 5.0 | 1.0 | 48.67 (± 1.86) | 5.27 (± 0.26) | 2.56 (± 0.10) | 97.3 | 105.4 | 98.0 |
| Urine 3 | – | – | 3.16 (± 0.14) | 20.0 | 2.0 | 3.0 | 20.36 (± 0.94) | 2.07 (± 0.09) | 6.09 (± 0.28) | 101.8 | 103.5 | 97.7 |
aAll human urine samples were collected from the laboratory personnel
bAverage ± confidence interval, the confidence level is 95%