Literature DB >> 32777216

Post-Bentall Ascending Aortic Pseudoaneurysm Due to Coronary Button Dehiscence.

Kothandam Sivakumar1, Pramod Sagar2.   

Abstract

Ascending aortic pseudoaneurysms after the Bentall procedure caused by proximal or distal anastomotic or coronary dehiscence could carry high operative risks. One report in literature has described transcatheter management for distal anastomotic dehiscence using a vascular plug. A similar management of proximal anastomotic or coronary dehiscence may affect valve function and coronary flows. A successful nonsurgical closure of a left coronary dehiscence aided by multimodal imaging and its short-term follow-up is described.
Copyright © 2021 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

Entities:  

Year:  2020        PMID: 32777216     DOI: 10.1016/j.athoracsur.2020.05.184

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330