Literature DB >> 32767779

The impact of minimally invasive root canal preparation strategies on the ability to shape root canals of mandibular molars.

C O Lima1, A F A Barbosa1, C M Ferreira1, C M Augusto1, L M Sassone1, R T Lopes2, S R Fidel1, E J N L Silva1,3.   

Abstract

AIM: To evaluate the use of a reduced taper endodontic instrument system (Bassi Logic™ .03 taper) and expandable heat-treated system (XP-endo Shaper) on the ability to shape canals in mandibular molars, by means of microcomputed tomography (micro-CT) analysis. The Reciproc system was used as the reference for comparison.
METHODOLOGY: Twenty-four mandibular molars were scanned in a micro-CT, matched based on similar anatomical features and sorted into three groups (n = 8 per group), according to root canal preparation system: Bassi Logic™ .03, XP-endo Shaper and Reciproc. The teeth were mounted onto a mannequin and the pulp chambers were accessed with traditional access cavities. In Bassi Logic™ .03 and Reciproc groups, mesial canals were prepared with size 25, .03 taper or R25 (size 25, .08v taper) instruments and the distal root canal with size 25, .03 taper and size 40, .03 taper or R25 and R40 (size 40, .06v taper), respectively. In XP-endo Shaper groups, all root canals were prepared with XP-endo Shaper (size 30, .04v taper). After root canal preparation, the teeth were rescanned. The percentage of untouched canal areas and the percentage of removed dentine were evaluated separately for mesial and distal root canals. The data were analysed using one-way anova and Tukey tests (P < 0.05).
RESULTS: The Bassi Logic™ .03 group was associated with a greater percentage of untouched canal areas when compared to XP-endo Shaper and Reciproc groups for mesial and distal root canals (P < 0.05), but no differences were found between XP-endo Shaper and Reciproc groups (P > 0.05). No significant difference was observed in the percentage of dentine removed amongst the groups for mesial and distal root canals (P > 0.05).
CONCLUSION: The use of a reduced taper system (Bassi Logic™ .03) during root canal preparation resulted in a greater percentage of untouched canal areas when compared to XP-endo Shaper and Reciproc instruments. No differences were observed amongst the systems regarding the percentage of dentine removed.
© 2020 International Endodontic Journal. Published by John Wiley & Sons Ltd.

Keywords:  XP-endo Shaper; mandibular molars; micro-CT; root canal treatment; taper

Mesh:

Year:  2020        PMID: 32767779     DOI: 10.1111/iej.13384

Source DB:  PubMed          Journal:  Int Endod J        ISSN: 0143-2885            Impact factor:   5.264


  2 in total

1.  Antimicrobial and cytotoxic activity of electrosprayed chitosan nanoparticles against endodontic pathogens and Balb/c 3T3 fibroblast cells.

Authors:  Amir Ibrahim; Desigar Moodley; Cosmas Uche; Ernest Maboza; Annette Olivier; Leslie Petrik
Journal:  Sci Rep       Date:  2021-12-29       Impact factor: 4.379

2.  Shaping ability of four single-file systems in the instrumentation of second mesiobuccal canals of three-dimensional printed maxillary first molars.

Authors:  Fulu Xu; Yuerong Zhang; Yongchun Gu; Yifan Ping; Ruyu Zhou; Juan Wang
Journal:  Ann Transl Med       Date:  2021-09
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.