| Literature DB >> 32766070 |
Xiaodong Zheng1,2, Hiroko Yamada1, Tomoyuki Kamao1, Tomoko Goto2, Atsushi Shiraishi1.
Abstract
BACKGROUND: Before blepharoptosis surgery, simulation of eyelid features, including lid height and crease position, is often performed. However, discrepancies of the simulation and outcome can occur. The purpose of this study was to analyze the pre- and postoperative images and to evaluate factors contributing to the discrepancies.Entities:
Year: 2020 PMID: 32766070 PMCID: PMC7339311 DOI: 10.1097/GOX.0000000000002923
Source DB: PubMed Journal: Plast Reconstr Surg Glob Open ISSN: 2169-7574
Fig. 1.Preoperative simulation of the upper eyelid appearance after blepharoptosis surgery. The inner wire of a lacrimal tube (A) was bent to a semicircle (B). The ptotic eyelid (C) was pushed up by the wire at the line selected for the eyelid crease to simulate the postoperative eyelid appearance (D).
Fig. 2.Digital image analyses of the eyelid features were performed by the ImageJ software. The following parameters were measured: A, MRD-1, distance between upper eyelid margin and corneal light reflex; B, PTS, distance between the upper eyelid margin and lid crease; C, FH, distance between the center of upper and lower eyelids margins; and D, OSA, the area surrounded by the upper and lower margins of the eyelid.
Representative ICC of ImageJ Analysis (OSA)
| Reliability and Reproducibility | ICC* | 95% Confidence Interval | ||
|---|---|---|---|---|
| Lower | Upper | |||
| X.Z. repeat test (reliability) | 0.9782 | 0.9724 | 0.9833 | <0.001 |
| T.G. repeat test (reliability) | 0.9636 | 0.9618 | 0.9782 | 0.003 |
| X.Z. and T.G. repeat test (reproducibility) | 0.9524 | 0.9468 | 0.9874 | 0.008 |
*The reliability of ImageJ analysis of the eyelid features was evaluated by calculating the ICCs for all parameters measured. A representative result of OSA is shown.
ICC, intra/interclass correlation coefficients.
Correlation Analyses of Factors Related to Simulation Errors of MRD-1 and PTS
| Simulation Error of MRD-1 | Simulation Error of PTS | |
|---|---|---|
| Length of skin resection | r = 0.366, | r = 0.332, |
| Width of skin resection | r = 0.411, | r = 0.223, |
| Preoperative OSA | r = 0.058, | r = −0.588, |
| Preoperative MRD-1 | r = −0.082, | |
| Fissure height | r = −0.132, | r = −0.182, |
| Levator function | r = 0.085, | r = 0.144, |
r, Spearman correlation coefficient.
Fig. 3.Preoperative simulation and postoperative outcome following blepharoptosis surgery. Representative cases showing less skin resection (left) had a good predictability of postoperative MRD-1 and large skin resection (right) resulted in poor prediction. Image of the extent of skin resection is outlined as the yellow area.