| Literature DB >> 32763473 |
Hua Yang1, Jiajia Hu2, Ping Li3, Chengliang Zhang4.
Abstract
BACKGROUND: To review the effect of ultraviolet germicidal irradiation (UVGI) as a disinfection method for filtering facepiece respirators (FFRs) to facilitate reuse during COVID-19 pandemic.Entities:
Keywords: COVID-19 pandemic; Decontamination; Filtering facepiece respirators; N95; Reuse; Ultraviolet germicidal irradiation
Mesh:
Year: 2020 PMID: 32763473 PMCID: PMC7402378 DOI: 10.1016/j.pdpdt.2020.101943
Source DB: PubMed Journal: Photodiagnosis Photodyn Ther ISSN: 1572-1000 Impact factor: 3.631
Researches of ultraviolet germicidal irradiation for filtering facepiece respirators disinfection.
| Year | First author | Pathogens | FFRs | Decontamination treatments | Laboratory conditions | UVGI methods | Research items |
|---|---|---|---|---|---|---|---|
| 2009 | Viscusi | None | Three N95 FFR models, three surgical N95 respirator models, Three models of P100 FFRs | UVGI, EtO, VHP, microwave, bleach | T 21 ± 2℃, RH 50 ± 10 % | FFRs fitted with a 40-W UV-C light (average UV intensity range from | Filter aerosol penetration, filter airflow resistance. |
| 2011 | Viscusi | None | 3 M 1870, 3 M 1860s | UVGI, MGS, and MH | T 21 ± 2℃, RH 50 ± 10 % | FFRs fitted with a 40-W UV-C light (UV intensity | FFRs in fit, odor detection, comfort, and donning difficulty |
| 2011 | Heimbuch | Influenza A | Three N95 FFR models (3 M 8210, 3 M 8000, Moldex 2200) and three surgical N95 respirator models (PFR95−270, 3 M 1870, 3 M 1860) | MGS, WMH, and UVGI | T 22 ± 2℃, RH 75 ± 5% | 120 cm × 25 cm box, 80-W UV-C, | Concentration of viable virus |
| 2012 | Lore | Influenza A/H5N1 | 3 M models 1860s and 1870 108 FFRs | UVGI, MGS, and MH | T 22 ± 2℃, RH > 60 % | Virus concentrations, virus extraction efficiency, virus culture quantification | |
| 2015 | Lindsley | None | 3 M 1860, 3 M 9120, GE 1730, 3 M KC 46,727 | UVGI | T 27 ± 1.7℃, RH 25 ± 6.5 % | The FFRs were exposed to 15-W, | Filter penetration, and flow resistance |
| 2018 | Mills | H1N1 influenza | Fifteen NIOSH-approved N95 FFR | UVGI | T 21 ± 2℃, RH 48 ± 6% | a UV dose of | Viable virus recovered from each sampled location |
| 2020 | Liao | None | 3 M 8210, 4C Air, ESound, Onnuriplan | heat under various humidities, steam, alcohol, diluted chlorine-based solution, UVGI | Not mentioned | UV-C with an intensity of 8 W, Samples were irradiated for 30 min and left to stand under ambient conditions for 10 min per cycle | degradation efficiency, meltblown fabrics resistence |
EtO: ethylene oxide; VHP: vaporized hydrogen peroxide; UVGI: ultraviolet germicidal irradiation; MGS: microwave-generated steam; WMH: warm moist heat; UV-C: UVC: ultraviolet C; UV: ultraviolet; FFR: filtering facepiece respirator; NIOSH: National Institute for Occupational Safety and Health; T: temperature; RH, relative humidity.