Literature DB >> 3275110

Analysis of thallium-201 myocardial SPECT images using fuzzy set theory.

M Jamzad1, A Uchiyama, H Toyama, H Murata.   

Abstract

Using the fuzzy set theory, a method was developed for analyzing the extent and severity of ischemia by comparing the exercise and delayed SPECT images with Thallium-201. For each short axial image (slice) for exercise and delayed study, a defect probability matrix (DPM) is created so that it shows the severity of ischemia of myocardium in that slice. Each slice is divided into 8 equi-angle sectors, and the left ventricle (LV) also is divided into 8 equi-angle vertical sectors from apex to base. Using DPMs, the defect probability is calculated for each slice, sectors of each slice and vertical sectors of the LV. The results are displayed on a CRT by means of images, curves and histograms. They show what percentage of the area of each slice and that of the lateral, anterior, septum and inferior portions have how much defect. They provide comprehensive and easily understood information about the condition of the LV in exercise and delayed stages. Persistent and transient ischemia can be diagnosed by visual comparison of patients' curves and histograms with their corresponding normal limits.

Entities:  

Mesh:

Substances:

Year:  1988        PMID: 3275110     DOI: 10.1007/bf03164947

Source DB:  PubMed          Journal:  Ann Nucl Med        ISSN: 0914-7187            Impact factor:   2.668


  5 in total

1.  [A method for the quantitative evaluation of myocardial SPECT images with a three-dimensional display--STEREO-VIEW].

Authors:  H Toyama; H Matsuda; H Murata; M Akisada
Journal:  Kaku Igaku       Date:  1987-07

2.  "Circumferential profiles:" a new method for computer analysis of thallium-201 myocardial perfusion images.

Authors:  R D Burow; M Pond; A W Schafer; L Becker
Journal:  J Nucl Med       Date:  1979-07       Impact factor: 10.057

3.  Transaxial tomography with thallium-201 for detecting remote myocardial infarction. Comparison with planar imaging.

Authors:  J L Ritchie; D L Williams; G Harp; J L Stratton; J H Caldwell
Journal:  Am J Cardiol       Date:  1982-12       Impact factor: 2.778

4.  A comparison between conventional scintigraphy and emission tomography with thallium-201 in the detection of myocardial infarction: concise communication.

Authors:  J Maublant; J Cassagnes; J J Le Jeune; D Mestas; A Veyre; H Jallut; G Meyniel
Journal:  J Nucl Med       Date:  1982-03       Impact factor: 10.057

5.  Quantification of rotational thallium-201 myocardial tomography.

Authors:  E V Garcia; K Van Train; J Maddahi; F Prigent; J Friedman; J Areeda; A Waxman; D S Berman
Journal:  J Nucl Med       Date:  1985-01       Impact factor: 10.057

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.