Literature DB >> 32750665

Challenges in use of saliva for detection of SARS CoV-2 RNA in symptomatic outpatients.

Marie L Landry1, Jody Criscuolo2, David R Peaper3.   

Abstract

BACKGROUND: A major expansion in SARS CoV-2 testing is urgently needed. Saliva is an attractive option as an alternative for nasopharyngeal swabs (NPS), since saliva can be self-collected, is non-invasive, and sample quality is not dependent on the expertise of the collector.
OBJECTIVE: To compare SARS CoV-2 positivity on paired NPS and saliva samples. STUDY
DESIGN: NPS and paired saliva samples were prospectively collected from symptomatic outpatients suspected of having COVID-19 and were tested by real-time RT-PCR.
RESULTS: In total, 35/124 (26.6 %) samples were RT-PCR positive, with 33/35 positive by NPS (sensitivity = 94.3 % (95 % CI 81.4%-99.0%)) and 30/35 by pure saliva (sensitivity = 85.7 % (95 % CI 70.6%-93.7%)), for an overall agreement of 117/124 (94.4 %). The median cycle threshold value was significantly lower for NPS than for saliva (p = 0.0331). A third or more of pure saliva samples from symptomatic patients were thick, stringy, and difficult to pipet.
CONCLUSIONS: Real-time RT-PCR of pure saliva had an overall sensitivity for SARS CoV-2 RNA detection of 85.7 % when compared to simultaneously collected NPS. Our study highlighted the need to optimize collection and processing before saliva can be used for high volume testing.
Copyright © 2020 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  COVID-19; Nasopharyngeal swab; Real-time RT-PCR; SARS CoV-2; Saliva

Mesh:

Substances:

Year:  2020        PMID: 32750665      PMCID: PMC7392849          DOI: 10.1016/j.jcv.2020.104567

Source DB:  PubMed          Journal:  J Clin Virol        ISSN: 1386-6532            Impact factor:   3.168


Introduction

A major expansion in SARS CoV-2 testing is urgently needed. In the U.S., in addition to symptomatic patients, testing may be undertaken for all hospital admissions, prior to immunosuppression or invasive medical procedures, and may be considered for asymptomatic nursing home residents, healthcare workers, first responders, residential college students, correctional facilities, and employees in various work settings. Although nasopharyngeal swabs (NPS) are widely considered to be the preferred specimen for SARS-CoV-2 testing [1], obstacles to collection include lack of swabs and transport media, the need for skilled staff and personal protective equipment (PPE) for NPS collection, risk of exposure for the collector if coughing or sneezing is induced, and discomfort for the patients that may preclude recurrent testing. In addition, the quality of NPS specimen obtained can be highly variable and in some cases, falsely negative. Thus, alternative sample types are being explored to meet the diagnostic and public health goals for COVID-19 testing. Saliva is an attractive option as an alternative specimen for NPS. It can be self-collected non-invasively, and sample collection is not dependent on the expertise the collector. However, data on the utility of saliva for SARS CoV-2 are minimal. In reviewing the literature, many different collection methods are reported, including swabbing the mouth, coughing to generate saliva-sputum mixtures, and dilution in viral transport media (VTM). The recently issued Infectious Diseases Society of America (IDSA) guidelines state that saliva as the sole sample source for COVID-19 diagnosis cannot be recommended due to a paucity of studies of pure saliva [1].

Methods

To investigate the utility of saliva as an alternate sample type, during a two week period April 16 to April 28, 2020, 124 NPS in 3 mL universal transport medium (Becton Dickinson) and paired saliva samples were prospectively collected at Yale New Haven Hospital drive-through testing sites from symptomatic outpatients suspected of having COVID-19. Patients were asked to not eat or drink for 30 min, let saliva pool in their mouths and then spit into sterile containers. Samples were kept in a cooler and delivered within 2 h to the laboratory. NPS were tested on the day of collection. Residual NPS samples and their paired saliva samples were frozen on day of receipt at -70 C. Within 2 weeks, positive NPS and all 124 saliva samples were thawed and tested. Nucleic acid was extracted from 200 μL of sample and eluted in 55 μL using EasyMag (bioMerieux, Durham, NC). Reverse-transcriptase PCR was performed using a Emergency Use Authorized laboratory developed assay based on the Centers for Disease Control and Prevention protocol. Cycle threshold (Ct) values were recorded for N1, N2 and RNAse P for each sample. Saliva specimens that were viscous and difficult to pipette were treated with sputasol (Thermo Scientific) to liquify the sample.

Results

Overall, 33/124 NPS (26.6 %) were PCR positive, and saliva was also positive for 28 of these 33 (84.8 %) NPS-saliva pairs. For the 91 negative NPS, 2 (2.2 %) of the paired saliva samples were PCR-positive. These two NPS negative/ saliva positive pairs were reextracted and retested and results were confirmed (Table 1 ). In total, 35 samples were RT-PCR positive, with 33/35 positive by NPS (sensitivity = 94.3 % (95 % CI 81.4%–99.0%)) and 30/35 by pure saliva (sensitivity = 85.7 % (95 % CI 70.6%–93.7%)), for an overall agreement of 117/124 (94.4 %) between the two sample types. These data give a Cohen’s kappa of 0.851 (95 % CI 0.745 to 0.958). The Ct values for N2 for each result type are shown in Fig. 1 A. For pairs in which both NPS and saliva were positive, Ct values ranged from 14.8 to 40, but samples testing positive only in one specimen had Ct values above 30. For 23 (69.7 %) of 33 pairs, Ct values were lower for NPS samples than for saliva (Fig. 1B), and the difference in median Ct value was significant (p = 0.0331). Despite the high variability of N2 Ct values seen in these samples, there was little variation in Ct values for RNAse P, a marker of human cellular content and a surrogate for sample quality (Fig. 1C).
Table 1

SARS CoV-2 real-time RT PCR results for paired NPS and saliva in symptomatic outpatients.

NP Swab
PositiveNegativeTotal
SalivaPositive28230
Negative58994
Total3391124
Fig. 1

Cycle threshold (Ct) values for N2 and RNAse P (RP) for NPS and saliva specimens. A) N2 Ct values by testing concordance. The N2 Ct value was set to 41 for samples in which only the N1 target was detected. The horizontal dashed line is at Ct = 40, the assay cut-off. Horizontal lines indicate the median and interquartile range (IQR). The median and IQR for each group are: 28.56 (18.3 to 33.5), 30.18 (20.32 to 36.66), 33.68 (32.5 to 37.99), and 37.62 (36.98 to 38.26) for Both (NPS), Both (Saliva), NPS Only, and Saliva Only, respectively. B) N2 Ct values for paired NPS and saliva samples. Pairs are connected by a line. The N2 Ct was set to 41 for samples in which N2 was not detected including those negative for SARS-CoV-2 RNA. The horizontal dashed line is at Ct = 40, the assay cut-off. Ct values were significantly lower for NPS when compared by Wilcoxon matched-pairs signed rank test (p = 0.0331). C) RP Ct values for NPS and saliva specimens. Median and IQR are 24.27 (23.46 to 24.96) and 22.63 (21.88 to 23.85), respectively.

SARS CoV-2 real-time RT PCR results for paired NPS and saliva in symptomatic outpatients. Cycle threshold (Ct) values for N2 and RNAse P (RP) for NPS and saliva specimens. A) N2 Ct values by testing concordance. The N2 Ct value was set to 41 for samples in which only the N1 target was detected. The horizontal dashed line is at Ct = 40, the assay cut-off. Horizontal lines indicate the median and interquartile range (IQR). The median and IQR for each group are: 28.56 (18.3 to 33.5), 30.18 (20.32 to 36.66), 33.68 (32.5 to 37.99), and 37.62 (36.98 to 38.26) for Both (NPS), Both (Saliva), NPS Only, and Saliva Only, respectively. B) N2 Ct values for paired NPS and saliva samples. Pairs are connected by a line. The N2 Ct was set to 41 for samples in which N2 was not detected including those negative for SARS-CoV-2 RNA. The horizontal dashed line is at Ct = 40, the assay cut-off. Ct values were significantly lower for NPS when compared by Wilcoxon matched-pairs signed rank test (p = 0.0331). C) RP Ct values for NPS and saliva specimens. Median and IQR are 24.27 (23.46 to 24.96) and 22.63 (21.88 to 23.85), respectively.

Discussion

There is tremendous interest in using saliva for detection of SARS CoV-2 RNA, especially for large scale and repeated testing of high risk populations. Our results were virtually identical to those obtained from a similar prospective study in symptomatic outpatients by Williams et al. in Australia [2]. In that study, 33/39 (84.6 %) of patients with positive NPS had SARS CoV-2 RNA detected in saliva, and 1/50 (2%) of saliva samples from patients with negative NPS were also positive. Similar to our findings, Ct values were lower in NPS than in saliva. Reports by Azzi et al. in a subset of known NPS-positive hospitalized patients in Italy have found saliva collected by the drooling technique can be positive when a subsequent NP swab is negative [3,4]. Another study of 12 hospitalized patients in Hong Kong using coughed saliva found 11/12 NPS-positive patients were also saliva PCR-positive [5]. In a recent study, known NPS-positive hospitalized patients had saliva and repeat NPS collected every 3 days, and more saliva samples were positive than repeat NPS [6]. In the same report, serial paired samples in asymptomatic healthcare workers found two individuals with SARS CoV-2 RNA at low levels in saliva, but not in self-collected NPS. In contrast to other reports, viral loads were lower and more variable in NPS than in saliva samples. However, the Ct values for the RNase P (RP) control were significantly higher and more variable for NPS samples than for saliva, suggesting that variable NPS sample quality in both patient groups could have contributed to poor NPS results. We found very little variation in RP Ct values in NPS samples in our study (Fig. 1C). In a recent prospective study of NPS-saliva pairs using Cepheid Xpert Xpress SARS- CoV-2 RT-PCR (Sunnyvale, CA), only the liquid, non-viscous components of each specimen were drawn into the disposable pipets for test cartridge inoculation [7]. Overall 50/156 samples were positive, 47 by both NPS and saliva, 2 by NPS only and 1 by saliva only. However, the GeneXpert platform has limited product availability and is also not suitable to high volume testing. In our study, a significant finding was that a third or more of saliva samples from sick outpatients were thick, stringy, and difficult to pipet, requiring sputasol treatment. These obstacles greatly slowed processing, and risked contamination of the workspace during pipetting. For high volume testing, liquid samples that are readily aspirated by robotic instruments are essential to an efficient workflow. While thick saliva may be more frequently encountered in potentially dehydrated symptomatic outpatients, from our experience it can also occur in about 10 % of asymptomatic volunteers. Three laboratories in the U.S. have now received EUA for saliva testing by SARS CoV-2 PCR, and use saliva collection devices commonly used for genetic testing. These devices facilitate collection of a standard sample volume by filling up to a line on the device, add a preservative to prevent viral RNA degradation during transport, and promote liquefaction of the sample to facilitate processing. In summary, our prospective study in symptomatic outpatients found an overall sensitivity for SARS CoV-2 detection of 85.7 % for pure saliva when compared to simultaneously collected NPS. However, our study highlights the difficulty in using pure saliva for high volume testing and the need to optimize saliva collection and processing. Thus, studies are currently in progress to evaluate saliva collection devices on ease of pipetting using liquid handlers and sensitivity of detection.

Research funding

No research support was received for this work. The work was performed as part of routine clinical laboratory operations.

CRediT authorship contribution statement

Marie L. Landry: Conceptualization, Methodology, Validation, Resources, Data curation, Writing - original draft, Writing - review & editing, Supervision, Project administration. Jody Criscuolo: Investigation, Validation, Data curation. David R. Peaper: Writing - review & editing, Formal analysis.

Declaration of Competing Interest

The authors have no conflicts to declare.
  51 in total

1.  Comparison of Saliva and Nasopharyngeal Swab Nucleic Acid Amplification Testing for Detection of SARS-CoV-2: A Systematic Review and Meta-analysis.

Authors:  Guillaume Butler-Laporte; Alexander Lawandi; Ian Schiller; Mandy Yao; Nandini Dendukuri; Emily G McDonald; Todd C Lee
Journal:  JAMA Intern Med       Date:  2021-03-01       Impact factor: 21.873

2.  Clinical Validation of a Sensitive Test for Saliva Collected in Health Care and Community Settings with Pooling Utility for Severe Acute Respiratory Syndrome Coronavirus 2 Mass Surveillance.

Authors:  Nikhil S Sahajpal; Ashis K Mondal; Sudha Ananth; Allan Njau; Pankaj Ahluwalia; Vamsi Kota; Kevin Caspary; Ted M Ross; Michael Farrell; Michael P Shannon; Sadanand Fulzele; Alka Chaubey; Madhuri Hegde; Amyn M Rojiani; Ravindra Kolhe
Journal:  J Mol Diagn       Date:  2021-05-04       Impact factor: 5.568

3.  Saliva Is a Promising Alternative Specimen for the Detection of SARS-CoV-2 in Children and Adults.

Authors:  Rebecca Yee; Thao T Truong; Pia S Pannaraj; Natalie Eubanks; Emily Gai; Jaycee Jumarang; Lauren Turner; Ariana Peralta; Yesun Lee; Jennifer Dien Bard
Journal:  J Clin Microbiol       Date:  2021-01-21       Impact factor: 5.948

Review 4.  The diagnostic accuracy of saliva testing for SARS-CoV-2: A systematic review and meta-analysis.

Authors:  Momen A Atieh; Marina Guirguis; Nabeel H M Alsabeeha; Richard D Cannon
Journal:  Oral Dis       Date:  2021-06-03       Impact factor: 4.068

5.  Rapid, point-of-care antigen and molecular-based tests for diagnosis of SARS-CoV-2 infection.

Authors:  Jacqueline Dinnes; Jonathan J Deeks; Sarah Berhane; Melissa Taylor; Ada Adriano; Clare Davenport; Sabine Dittrich; Devy Emperador; Yemisi Takwoingi; Jane Cunningham; Sophie Beese; Julie Domen; Janine Dretzke; Lavinia Ferrante di Ruffano; Isobel M Harris; Malcolm J Price; Sian Taylor-Phillips; Lotty Hooft; Mariska Mg Leeflang; Matthew Df McInnes; René Spijker; Ann Van den Bruel
Journal:  Cochrane Database Syst Rev       Date:  2021-03-24

6.  Severe Acute Respiratory Syndrome Coronavirus 2 Testing in Children in a Large Regional US Health System During the Coronavirus Disease 2019 Pandemic.

Authors:  David R Peaper; Christina Murdzek; Carlos R Oliveira; Thomas S Murray
Journal:  Pediatr Infect Dis J       Date:  2021-03-01       Impact factor: 2.129

7.  Comparison of saliva with healthcare workers- and patient-collected swabs in the diagnosis of COVID-19 in a large cohort.

Authors:  Mitnala Sasikala; Yelamanchili Sadhana; Ketavarapu Vijayasarathy; Anand Gupta; Sarala Kumari Daram; Naveen Chander Reddy Podduturi; Duvvur Nageshwar Reddy
Journal:  BMC Infect Dis       Date:  2021-07-05       Impact factor: 3.090

8.  A novel automated SARS-CoV-2 saliva PCR test protects a global asymptomatic workforce.

Authors:  Nikki Carter; Maryam Clausen; Rebecca A Halpin; Colin Blackmore; Kang Cai; Oona Delpuech; Alexander Kohlmann; Otto Magnusson; Ruth March; Daniel O'Neill; Kasthuri Prakash; James Sherwood; Tabetha Sundin; Jason Swift; Azar Tarakameh; Marilou Wijdicks; Daniel Wise; Mark Fidock
Journal:  Sci Rep       Date:  2021-06-16       Impact factor: 4.996

Review 9.  One-Year Update on Salivary Diagnostic of COVID-19.

Authors:  Douglas Carvalho Caixeta; Stephanie Wutke Oliveira; Leia Cardoso-Sousa; Thulio Marquez Cunha; Luiz Ricardo Goulart; Mario Machado Martins; Lina Maria Marin; Ana Carolina Gomes Jardim; Walter Luiz Siqueira; Robinson Sabino-Silva
Journal:  Front Public Health       Date:  2021-05-21

10.  Saliva sample and SARS-CoV-2 detection: More complexities than clarity.

Authors:  Sachin C Sarode; Gargi S Sarode
Journal:  J Oral Biol Craniofac Res       Date:  2021-07-13
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.