Thirty-day clinical outcomes of the Evolut PRO self-expanding transcatheter aortic valve: the international FORWARD PRO study.

Ganesh Manoharan1, Eberhard Grube, Nicolas M Van Mieghem, Stephen Brecker, Claudia Fiorina, Ran Kornowski, Haim Danenberg, Hendrik Ruge, Holger Thiele, Patrizio Lancellotti, Lars Søndergaard, Corrado Tamburino, Jae K Oh, Yunhua Fan, Stephan Windecker.   

Abstract

AIMS: The Evolut PRO is a new transcatheter heart valve with an outer pericardial wrap intended to reduce paravalvular leak and facilitate tissue ingrowth. We aimed to evaluate the clinical performance and safety of the Evolut PRO valve in standard practice. METHODS AND
RESULTS: FORWARD PRO is a prospective, multinational, multicentre observational study. Transcatheter aortic valve implantation with the Evolut PRO valve (23, 26, or 29 mm) was attempted in 629 non-consecutive patients from 39 centres from February 2018 to January 2019. The primary endpoint was the rate of all-cause mortality at 30 days compared to a pre-specified performance goal. An independent clinical events committee adjudicated safety endpoints based on VARC-2 definitions. All echocardiograms were centrally assessed by an independent core laboratory (Mayo Clinic, Rochester, MN, USA). Baseline characteristics included mean age 81.7±6.1 years, 61.8% female, STS score 4.7±3.3%, and 33.6% were frail. All-cause mortality at 30 days was 3.2%, which was lower than the pre-specified performance goal of 5.5% (p=0.004). Greater than mild AR was present in 1.8% of patients at discharge.
CONCLUSIONS: The FORWARD PRO study confirmed the safety and efficacy of the Evolut PRO transcatheter aortic valve system with an external pericardial wrap. ClinicalTrials.gov Identifier: NCT03417011

Entities:  

Mesh:

Year:  2020        PMID: 32748789     DOI: 10.4244/EIJ-D-20-00279

Source DB:  PubMed          Journal:  EuroIntervention        ISSN: 1774-024X            Impact factor:   6.534


  2 in total

Review 1.  Aortic Stenosis: New Insights in Diagnosis, Treatment, and Prevention.

Authors:  Saki Ito; Jae K Oh
Journal:  Korean Circ J       Date:  2022-10       Impact factor: 3.101

2.  Procedural Safety and Device Performance of the Portico™ Valve from Experienced TAVI Centers: 30-Day Outcomes in the Multicenter CONFIDENCE Registry.

Authors:  Helge Mollmann; Axel Linke; Luis Nombela-Franco; Martin Sluka; Juan Francisco Oteo Dominguez; Matteo Montorfano; Won-Keun Kim; Martin Arnold; Mariuca Vasa-Nicotera; Lenard Conradi; Anthony Camuglia; Francesco Bedogni; Ganesh Manoharan
Journal:  J Clin Med       Date:  2022-08-18       Impact factor: 4.964

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.