| Literature DB >> 32745627 |
Julia Alcoba-Florez1, Helena Gil-Campesino1, Diego García-Martínez de Artola1, Rafaela González-Montelongo2, Agustín Valenzuela-Fernández3, Laura Ciuffreda4, Carlos Flores5.
Abstract
OBJECTIVES: The ongoing COVID-19 pandemic continues to impose demands on diagnostic screening. In anticipation that the recurrence of outbreaks and the measures for lifting the lockdown worldwide may cause supply chain issues over the coming months, this study assessed the sensitivity of a number of one-step retrotranscription and quantitative polymerase chain reaction (RT-qPCR) solutions to detect SARS-CoV-2.Entities:
Keywords: COVID-19; Diagnosis; False negatives; SARS-CoV-2; Sensitivity; Solution comparisons
Mesh:
Substances:
Year: 2020 PMID: 32745627 PMCID: PMC7395224 DOI: 10.1016/j.ijid.2020.07.058
Source DB: PubMed Journal: Int J Infect Dis ISSN: 1201-9712 Impact factor: 3.623
Different RT-qPCR solutions evaluated for the detection of SARS-CoV-2 in nasopharyngeal swab samples from COVID-19 positive patients.
| Solution | #Targets | Target gene | Sensitivity, % (95% CI) | FN |
|---|---|---|---|---|
| TaqMan Fast Virus 1-Step Master Mix (Thermo Fisher Scientific) combined with validated primer-probe sets | 3 | E | 95.9 (89.9–98.9) | 4 |
| N | 75.5 (65.8–83.6) | 24 | ||
| RdRp | 77.6 (68.0–85.4) | 22 | ||
| LightMix® Modular SARS-CoV (COVID19) (TIB MOLBIOL) | 3 | E | 97.9 (92.8–99.7) | 2 |
| N | 78.6 (69.1–86.2) | 21 | ||
| RdRp | 89.8 (82.0–95.0) | 10 | ||
| SARS-COV-2 R-GENE (BioMérieux) | 3 | E | 65.3 (55.0–74.6) | 34 |
| N | 66.3 (56.1–75.6) | 33 | ||
| RdRp | 60.2 (49.8–70.0) | 39 | ||
| TaqPath COVID-19 CE-IVD RT-PCR Kit (Thermo Fisher Scientific) | 3 | ORF1ab | 65.3 (55.0–74.6) | 34 |
| S | 70.4 (60.3–79.2) | 29 | ||
| N | 76.5 (66.9–84.5) | 23 | ||
| Genesig Real-Time PCR COVID-19 kit (Primedesign Ltd.) | 1 | RdRp | 81.6 (72.5–88.7) | 18 |
| Real Accurate Quadruplex corona-plus PCR Kit (PathoFinder) | 1 | N | 83.7 (74.8–90.4) | 16 |
Specific primer-probes for SARS-CoV-2.
95% Confidence Interval.
False negative counts out of 98 patients.
Corman et al. (2020).
Fig. 1Raincloud plot of the distribution of cycle threshold (Ct) values for the RT-qPCR solutions evaluated for the detection of SARS-CoV-2 in COVID-19 positive samples. Raw Ct data with the median and the interquartile range are also represented and overlaid on each distribution.