Literature DB >> 32740865

Optimal target b-value on computed diffusion-weighted magnetic resonance imaging for visualization of pancreatic ductal adenocarcinoma and focal autoimmune pancreatitis.

Shintaro Ichikawa1, Marie-Luise Kromrey2,3, Utaroh Motosugi2,4, Hiroshi Onishi2.   

Abstract

PURPOSE: To compare computed diffusion-weighted imaging (cDWI) feasibility with that of directly acquired DWI for visualizing pancreatic ductal adenocarcinoma (PDAC) and focal autoimmune pancreatitis (AIP).
METHODS: From April 2012 to January 2017, 135 patients with PDAC (n = 111) or focal AIP (n = 24) were retrospectively enrolled. They underwent DWI with b-values of 0, 500, and 1000 s/mm2. From DWI0 and DWI1000, we generated cDWIs with targeted b-values of 1500, 2000, and 3000 s/mm2. The lesions' signal intensities, image quality, signal intensity ratio (SIR) of lesions and pancreatic parenchyma to spinal cord, and lesion-to-pancreatic parenchyma contrast ratio (CR) were compared among the five DWI protocols (DWI500, DWI1000, cDWI1500, cDWI2000, and cDWI3000). SIR was analyzed by receiver operating characteristic (ROC) analyses.
RESULTS: DWI500, DWI1000, and cDWI1500 had higher image quality than cDWI2000 and cDWI3000 (P < 0.001). The incidence of clear hyperintense PDAC was highest on cDWI2000, followed by cDWI1500, and cDWI3000 (P < 0.001-0.002), while the incidence of clear hyperintense AIP was higher on DWI1000, cDWI1500, and cDWI2000 than on DWI500 and cDWI3000 (P = 0.001-0.022). SIRs decreased whereas CRs increased as the b-value increased, for both PDAC and AIP. The area under the ROC curve (AUC) of SIRlesion was significantly lower on cDWI1500 than on cDWI2000 and cDWI3000 (P < 0.001).
CONCLUSION: cDWI1500 or cDWI2000 generated from b-values of 0 and 1000 s/mm2 were the most effective for visualizing PDAC and focal AIP; however, the SIRlesion AUC was significantly lower on cDWI1500 than on cDWI2000 and cDWI3000.

Entities:  

Keywords:  Adenocarcinoma; Autoimmune pancreatitis; Computed diffusion-weighted imaging; Magnetic resonance imaging; Pancreas

Mesh:

Year:  2020        PMID: 32740865     DOI: 10.1007/s00261-020-02695-0

Source DB:  PubMed          Journal:  Abdom Radiol (NY)


  2 in total

1.  High-Resolution, High b-Value Computed Diffusion-Weighted Imaging Improves Detection of Pancreatic Ductal Adenocarcinoma.

Authors:  Felix N Harder; Eva Jung; Sean McTavish; Anh Tu Van; Kilian Weiss; Sebastian Ziegelmayer; Joshua Gawlitza; Philip Gouder; Omar Kamal; Marcus R Makowski; Fabian K Lohöfer; Dimitrios C Karampinos; Rickmer F Braren
Journal:  Cancers (Basel)       Date:  2022-01-18       Impact factor: 6.639

2.  Magnetic Resonance Imaging of Peritoneal Carcinomatosis: Evaluation of High b-Value Computed Diffusion-Weighted Imaging.

Authors:  Maxime Ablefoni; Jakob Leonhardi; Constantin Ehrengut; Matthias Mehdorn; Robert Sucher; Ines Gockel; Timm Denecke; Hans-Jonas Meyer
Journal:  Curr Oncol       Date:  2022-06-29       Impact factor: 3.109

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.