Literature DB >> 32740710

Visualization of flow diverter stent wall apposition during intracranial aneurysm treatment using a virtually diluted cone beam CT technique (Vessel ASSIST).

Ameer E Hassan1,2, Jim Wise3, Elizabeth M Burke4, Wondwossen G Tekle5,6.   

Abstract

PURPOSE: Flow diverters (FD) have poor radiopacity, challenging visualization of deployment and vessel wall apposition with conventional neuroimaging modalities. We evaluated a novel cone beam computed tomography (CT) imaging technique that allows virtual dilution (VD) of contrast media to facilitate workflow and ensure accurate assessment of FD wall apposition.
METHODS: We retrospectively evaluated all patients treated for intracranial aneurysms with FD at our institution between November 2018 and November 2019. Undiluted injected dual cone beam CT acquisitions performed post-stenting were displayed with VD software (GE Healthcare). The resulting images were compared with conventional two-dimensional (2D) digital subtraction angiography (DSA) images. Two neurointerventionalists (Reader 1 and Reader 2, (R1, R2)) independently assessed FD deployment and wall apposition. Confidence in the diagnosis, inter-reader agreement, and X-ray exposure were assessed.
RESULTS: A total of 27 cases were reviewed. FD deployment and wall apposition scores were 4.2 ± 1.0 (R1) and 4.0 ± 1.1 (R2) for DSA and 3.7 ± 1.2 (R1) and 4.1 ± 1.0 (R2) for VD. Confidence in the diagnosis was improved with VD, with scores of 3.7 ± 0.7 (R1) and 4.0 ± 0.7 (R2) using DSA and 4.9 ± 0.2 (R1) and 4.9 ± 0.2 (R2) using VD (P < 0.001). Inter-reader agreement using 2D DSA was improved from moderate (0.49324) to good (0.7272) (P < 0.0001). There were no significant differences in inter-reader agreement in the deployment assessment (P = 0.68) or dose-area product (P = 0.54) between techniques.
CONCLUSION: VD imaging with dual cone beam CT enables accurate assessment of FD wall apposition after deployment with greater confidence and improved inter-reader agreement versus conventional 2D DSA alone, with comparable X-ray exposure.

Entities:  

Keywords:  Cone beam CT; Flow diverter; Imaging; Intracranial aneurysm; Virtual dilution

Year:  2020        PMID: 32740710     DOI: 10.1007/s00234-020-02507-8

Source DB:  PubMed          Journal:  Neuroradiology        ISSN: 0028-3940            Impact factor:   2.804


  1 in total

1.  Cone-beam CT angiography to assess the microvascular anatomy of intracranial arterial dissections.

Authors:  Francesco Diana; Eytan Raz; Francesco Biraschi; Daniele G Romano; Giada Toccaceli; Maksim Shapiro; Simone Peschillo
Journal:  Neuroradiol J       Date:  2021-09-30
  1 in total