Literature DB >> 32739160

Early outcomes with a hybrid technique for repair of a non-A non-B aortic dissection.

Weitie Wang1, Hulin Piao1, Yong Wang1, Bo Li1, Zhicheng Zhu1, Tiance Wang1, Kexiang Liu2.   

Abstract

OBJECTIVE: This study reports the early outcomes of patients with acute non-A non-B aortic dissection that involved the aortic arch but not the ascending aorta.
METHODS: From January 2013 to December 2018, 825 patients presented with aortic dissection. Of these, 28 patients with non-A non-B dissection (classified as dissection extending into the aortic arch with entry between the left common carotid artery and the left subclavian arteries) underwent a novel hybrid surgery. Self modified stent-grafts (Micropart Corp, Shanghai, China) were implanted via median sternotomy. Clinical presentation, postoperative data, and early outcomes were recorded.
RESULTS: All patients underwent an emergency operation. There were no in-hospital mortalities, reexplorations for hemorrhage, reports of paraplegia, cerebral infarctions, endoleaks, or left subclavian artery occlusions. No blood products were required during or after the operations. During the early follow-up at 39.12 ± 15.04 months (6.0-74.0 months), 1 patient was lost to follow-up, and 1 patient died suddenly. Computed tomography angiography showed false lumen patency persisted in the aortic arch and descending aorta without any symptoms. The 6-month computed tomography angiography showed significantly smaller distal aortic arch diameters (31.94 ± 6.95 mm) and descending aorta diameters (34.84 ± 4.15 mm) than measured preoperatively (36.76 ± 4.15 mm and 37.31 ± 4.7 mm, respectively). No paraplegia, cerebral infarction, upper limb ischemia, or left subclavian artery ischemia events were reported.
CONCLUSIONS: Our inclusion aortic arch technique is a safe, effective, and simple treatment for non-A non-B aortic dissections that can avoid endoleaks, requires no blood products, and has satisfactory early outcomes.
Copyright © 2020 The Author(s). Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  hybrid treatment; inclusion aortic arch technique; non-A non-B aortic dissection

Mesh:

Year:  2020        PMID: 32739160     DOI: 10.1016/j.jtcvs.2020.05.100

Source DB:  PubMed          Journal:  J Thorac Cardiovasc Surg        ISSN: 0022-5223            Impact factor:   5.209


  2 in total

1.  Non-A non-B acute aortic dissection with entry tear in the aortic arch.

Authors:  Monika Kosiorowska; Mikolaj Berezowski; Kazimierz Widenka; Maximilian Kreibich; Friedhelm Beyersdorf; Martin Czerny; Bartosz Rylski
Journal:  Interact Cardiovasc Thorac Surg       Date:  2022-05-02

2.  False lumen/true lumen wall pressure ratio is increased in acute non-A non-B aortic dissection.

Authors:  Naoyuki Kimura; Masanori Nakamura; Reiya Takagi; Makiko Naka Mieno; Atsushi Yamaguchi; Martin Czerny; Friedhelm Beyersdorf; Fabian Alexander Kari; Bartosz Rylski
Journal:  Interact Cardiovasc Thorac Surg       Date:  2022-08-03
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.