Literature DB >> 32739117

Transferability study of the BINACLE (binding and cleavage) assay for in vitro determination of botulinum neurotoxin activity.

Heike A Behrensdorf-Nicol1, Ursula Bonifas2, Jolanta Klimek2, Kay-Martin Hanschmann2, Brigitte G Dorner3, Christine Hohenadl4, Lars Töllner4, Birgit Kegel2, Beate Krämer2.   

Abstract

The muscle-relaxing effects of the botulinum neurotoxin (BoNT) serotypes A and B are widely used in clinical and aesthetic medicine. The standard method for measuring the biological activity of pharmaceutical BoNT products is a mouse bioassay. In line with the European Directive 2010/63/EU, a replacement by an animal-free method would be desirable. Whereas the existing approved in vitro methods for BoNT activity measurements are product-specific and not freely available for all users, the "binding and cleavage" (BINACLE) assay could become a widely applicable alternative. This method quantifies active BoNT molecules based on their specific receptor-binding and proteolytic properties and can be applied to all BoNT products on the European market. Here we describe the results of a transferability study, in which identical BoNT samples were tested in the BINACLE assay in four laboratories. All participants successfully performed the method and observed clear dose-response relationships. Assay variability was within an acceptable range. These data indicate that the BoNT BINACLE assay is robust and can be straightforwardly transferred between laboratories. They thus provide an appropriate basis for future studies to further substantiate the suitability of the BINACLE assay for the potency determination of BoNT products.
Copyright © 2020 International Alliance for Biological Standardization. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Activity testing in vitro; BINACLE (Binding and cleavage) assay; Botulinum neurotoxin serotype A; Botulinum neurotoxin serotype B; Transferability study

Mesh:

Substances:

Year:  2020        PMID: 32739117     DOI: 10.1016/j.biologicals.2020.06.007

Source DB:  PubMed          Journal:  Biologicals        ISSN: 1045-1056            Impact factor:   1.856


  1 in total

1.  Discrimination of the Activity of Low-Affinity Wild-Type and High-Affinity Mutant Recombinant BoNT/B by a SIMA Cell-Based Reporter Release Assay.

Authors:  Frank Neuschäfer-Rube; Andrea Pathe-Neuschäfer-Rube; Gerhard P Püschel
Journal:  Toxins (Basel)       Date:  2022-01-17       Impact factor: 4.546

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.