Literature DB >> 32738658

Slow degrading poly(glycerol sebacate) derivatives improve vascular graft remodeling in a rat carotid artery interposition model.

Jiayin Fu1, Xiaochu Ding1, Chelsea E T Stowell1, Yen-Lin Wu1, Yadong Wang2.   

Abstract

Porous synthetic grafts made of poly (glycerol sebacate) (PGS) can transform into autologous vascular conduits in vivo upon degradation of PGS. A long-held doctrine in tissue engineering is the necessity to match degradation of the scaffolds to tissue regeneration. Here, we tested the impact of degradation of PGS and its derivative in an interposition model of rat common carotid artery (CCA). Previous work indicates a complete degradation of PGS within approximately 2 weeks, likely at the fast end of the spectrum. Thus, the derivation of PGS focuses on delay degradation by conjugating the free hydroxy groups in PGS with a long chain carboxylic acid: palmitic acid, one of the most common lipid components. We evaluated two of the resultant palmitate-PGS (PPGS) in this study: one containing 9% palmitate (9-PPGS) and the other16% palmitate (16-PPGS). 16-PPGS grafts had the highest patency. Ultrasound imaging showed that the lumens of 16-PPGS grafts were similar to CCA and smaller than 9-PPGS and PGS grafts 12 weeks post-operation. Immunohistological and histological examination showed an endothelialized lumens in all three types of grafts within 4 weeks. Inflammatory responses to 16-PPGS grafts were limited to the adventitial space in contrast to a more diffusive infiltration in 9-PPGS and PGS grafts in week 4. Examination of calponin+ and αSMA+ cells revealed that 16-PPGS grafts remodeled into a distinctive bi-layered wall, while the walls of 9-PPGS grafts and PGS grafts only had one thick layer of smooth muscle-like cells. Correspondingly, the expression of collagen III and elastin displayed an identical layered structure in the remodeled 16-PPGS grafts, in contrast to a more spread distribution in 9-PPGS and PGS grafts. All the three types of grafts exhibited the same collagen content and burst pressure after 12 weeks of host remodeling. However, the compliance and elastin content of 16-PPGS grafts in week 12 were closest to those of CCA. Overall, placing the degradation of PGS derived elastomer to a window of 4-12 weeks results in vascular conduits closer to arteries in a rat carotid artery interposition model over a 12-week observation period.
Copyright © 2020 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Artery; Degradation; Tissue engineering; Vascular graft; poly(glycerol sebacate)

Year:  2020        PMID: 32738658     DOI: 10.1016/j.biomaterials.2020.120251

Source DB:  PubMed          Journal:  Biomaterials        ISSN: 0142-9612            Impact factor:   12.479


  5 in total

Review 1.  History, progress and future challenges of artificial blood vessels: a narrative review.

Authors:  Ke Hu; Yuxuan Li; Zunxiang Ke; Hongjun Yang; Chanjun Lu; Yiqing Li; Yi Guo; Weici Wang
Journal:  Biomater Transl       Date:  2022-03-28

Review 2.  Glycosaminoglycans: From Vascular Physiology to Tissue Engineering Applications.

Authors:  Antonio Junior Lepedda; Gabriele Nieddu; Marilena Formato; Matthew Brandon Baker; Julia Fernández-Pérez; Lorenzo Moroni
Journal:  Front Chem       Date:  2021-05-18       Impact factor: 5.221

3.  Gelatin/Polycaprolactone Electrospun Nanofibrous Membranes: The Effect of Composition and Physicochemical Properties on Postoperative Cardiac Adhesion.

Authors:  Xingang Wang; Li Xiang; Yongxuan Peng; Zihao Dai; Yuqing Hu; Xiaoting Pan; Xingliang Zhou; Hao Zhang; Bei Feng
Journal:  Front Bioeng Biotechnol       Date:  2021-12-06

4.  Mechanically reinforced biotubes for arterial replacement and arteriovenous grafting inspired by architectural engineering.

Authors:  Dengke Zhi; Quhan Cheng; Adam C Midgley; Qiuying Zhang; Tingting Wei; Yi Li; Ting Wang; Tengzhi Ma; Muhammad Rafique; Shuang Xia; Yuejuan Cao; Yangchun Li; Jing Li; Yongzhe Che; Meifeng Zhu; Kai Wang; Deling Kong
Journal:  Sci Adv       Date:  2022-03-16       Impact factor: 14.136

5.  Citrate Crosslinked Poly(Glycerol Sebacate) with Tunable Elastomeric Properties.

Authors:  Brandon B Risley; Xiaochu Ding; Ying Chen; Paula G Miller; Yadong Wang
Journal:  Macromol Biosci       Date:  2020-11-18       Impact factor: 4.979

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.