Literature DB >> 32738079

Sepsis from an apheresis platelet contaminated with Acinetobacter calcoaceticus/baumannii complex bacteria and Staphylococcus saprophyticus after pathogen reduction.

Joy L Fridey1, Susan L Stramer2, Ashok Nambiar3, Morvarid Moayeri3, Sonia Bakkour4, Charles Langelier5, Emily Crawford5, Thea Lu6, Marion C Lanteri6, Jack Kamm5, Steve Miller3, Stephen J Wagner7, Richard J Benjamin6, Michael P Busch4.   

Abstract

BACKGROUND: Strategies to reduce platelet (PLT) bacterial contamination include donor screening, skin disinfection, sample diversion, bacterial culture, pathogen reduction (PR), and day-of-transfusion tests. We report bacterial sepsis following a pathogen-reduced PLT transfusion. CASE REPORT: An adult male with relapsed acute lymphoblastic leukemia was successfully treated for central catheter-associated Staphylococcus aureus bacteremia. A peripherally inserted central catheter (PICC) was placed. Chills, rigors, and flushing developed immediately after PICC-infused pathogen-reduced PLTs, progressing to septic shock requiring intensive care management.
METHODS: PICC and peripheral blood (PB), transfused bag saline flushes (TBFs), environmental samples, and the pathogen-reduced untransfused co-component (CC) were cultured. Plasma metagenomic and bacterial isolate whole-genome sequencing; PLT mitochondrial DNA (mtDNA) testing of untransfused CC and TBF; CC testing for amotosalen (S-59)/S-59 photoproducts; isolate PR studies (INTERCEPT); and TBF polymerase chain reaction for recipient Y-chromosome DNA were performed.
RESULTS: PB and PICC cultures grew Acinetobacter calcoaceticus/baumannii complex (ACBC). TBF was gram-positive; mass spectrometry identified ACBC and Staphylococcus saprophyticus (SS). CC Gram stain and cultures were negative. Environmental cultures, some done after decontamination, were ACBC/SS negative. Posttransfusion patient plasma and TBF ACBC sequences were genetically identical. No Y-chromosome signal was detected in TBF. S-59 photoproducts and evidence of mtDNA amplification inhibition were found in the CC. Spiking PR studies showed >5.9-log inactivation for both isolates. Donor skin cultures for Acinetobacter were negative.
CONCLUSION: CC sterility, PR studies, residual S-59 photoproducts, and mtDNA amplification inhibition suggest successful PR. Unidentified environmental sources and inherent or acquired bag defects may have contributed to postmanufacturing pathogen-reduced PLT contamination.
© 2020 AABB.

Entities:  

Keywords:  Acinetobacter calcoaceticus/baumannii; Staphylococcus saprophyticus; pathogen reduction; septic transfusion reaction

Year:  2020        PMID: 32738079     DOI: 10.1111/trf.15951

Source DB:  PubMed          Journal:  Transfusion        ISSN: 0041-1132            Impact factor:   3.157


  2 in total

1.  Acquired platelet storage container leaks and contamination with environmental bacteria: A preventable cause of bacterial sepsis.

Authors:  Richard R Gammon; Rita A Reik; Marc Stern; Ralph R Vassallo; Dan A Waxman; Pampee P Young; Richard J Benjamin
Journal:  Transfusion       Date:  2021-12-20       Impact factor: 3.337

2.  Evaluation of an improved rapid bacterial assay with untreated and pathogen-reduced platelets: Detection of Acinetobacter strains.

Authors:  David LaVerda; Lisa Shinefeld; Nancy Best; Johny Lisitu; Gary Tambolleo; Yli Remo Vallejo
Journal:  Transfusion       Date:  2021-05-27       Impact factor: 3.337

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.