Literature DB >> 32735039

Precision and accuracy of robot-assisted technology with simplified express femoral workflow in measuring leg length and offset in total hip arthroplasty.

Andrea Cozzi Lepri1,2, Marco Villano1,2, Matteo Innocenti1,2, Tommaso Porciatti1,2, Fabrizio Matassi1,2, Roberto Civinini1,2.   

Abstract

BACKGROUND: Semi-active robot-assisted total hip arthroplasty (THA) has two options to measure the leg length discrepancy (LLD) and combined offset (CO), the 'enhanced' femoral workflow and the so-called 'express' simplified workflow. The purpose of this study was to determine the precision and accuracy of intraoperative LLD and CO measurement with express workflow robotic THA.
METHODS: Between February 2018 and December 2019, 30 patients underwent an express workflow robot-assisted primary THA for intraoperative LLD and CO measurements. Postoperative radiographs were used for LLD and CO measurement. In order to examine the accuracy of the robotic system assessment, the absolute difference between the robotic assessments and radiographic evaluations was calculated.
RESULTS: Intraoperative robotic measurements reported a mean error of 0.2-0.6 mm for each registration, with no significant difference between them (p = 0.311). The average absolute discrepancies between the robotic and radiographic assessments in the LLD and CO measurements were 1.3 ± 1.5 mm (p = 0.17) and 1.1 ± 0.9 mm (p = 0.11), respectively, while the Pearson's correlation coefficients were 0.69 and 0.71.
CONCLUSIONS: An external marker without a femoral array inserted into a screw positioned in the greater trochanter would be an easier and faster method to measure LLD and CO. Our study showed that the measured values of LLD and CO obtained by intraoperative express workflow robot-assisted THA system were precise and accurate.
© 2020 John Wiley & Sons Ltd.

Entities:  

Keywords:  combined offset; express femoral workflow; leg length discrepancy; robot-assisted technology; total hip arthroplasty

Year:  2020        PMID: 32735039     DOI: 10.1002/rcs.2141

Source DB:  PubMed          Journal:  Int J Med Robot        ISSN: 1478-5951            Impact factor:   2.547


  1 in total

1.  Robotic-assisted versus manual total hip arthroplasty in obese patients: a retrospective case-control study.

Authors:  Shuai Zhang; Yubo Liu; Minzhi Yang; Mingyang Ma; Zheng Cao; Xiangpeng Kong; Wei Chai
Journal:  J Orthop Surg Res       Date:  2022-07-30       Impact factor: 2.677

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.