Literature DB >> 32730907

New insights into the lacrimal pump.

Mohammad Javed Ali1, Maximilian Zetzsche2, Michael Scholz2, Dieter Hahn3, Simone Gaffling3, Jens Heichel4, Christian Manfred Hammer2, Lars Bräuer2, Friedrich Paulsen5.   

Abstract

PURPOSE: To date, there are many theories about tear transport through the canaliculi of the draining lacrimal system into the lacrimal sac but only few with supportive data. It is certain that the function of the lacrimal part of orbicularis oculi muscle (Horner-Duverney's muscle) is indispensable for the transport of "used" tears. However, the muscle's exact structure and the mechanisms of its functions are as yet unclear. To obtain deeper insights we undertook the present study.
METHODS: Upper and lower canaliculi (including the entrance into the lacrimal sac) from donor cadavers were dissected. Some of the specimens were prepared for scanning electron microscopy (SEM) to analyze the course of muscle fibers surrounding the canaliculi. Others were sectioned for enzyme- (EHC) and immunohistochemistry (IHC) to learn about the distribution of slow and fast reacting muscle fibers in Horner-Duverney's muscle as well as to analyze the distribution of different neurotransmitters to learn more about the innervation of Horner-Duverney's muscle. Four tear duct systems taken from body donors were cut out en bloc after formalin fixation, serially sectioned and reconstructed using a newly developed technology for 3D reconstruction of histological serial sections named HiD® (Chimaera GmbH, Germany). Patients that had undergone dacryocystorhinostomy (DCR) were video-analyzed endonasally during active blinking, focusing on viewing the temporal wall of the lacrimal sac movement where the canaliculi penetrated the lacrimal sac.
RESULTS: SEM revealed that muscle fibers of Horner-Duverney's muscle surround the vertical parts of the upper and lower canaliculus in a scissor like pattern whereas they ran in parallel to the first two thirds of the horizontal parts surrounding the respective canaliculus. Here, the muscle fibers were embedded in dense connective tissue forming a unique network. At the nasal third, muscle fibers left the canaliculi and ran to the posterior part of the fascia of the lacrimal sac and the lacrimal bone. EHC revealed that Horner-Duverney's muscle contained nearly an equal distribution of type I and type IIb muscle fibers compared to the superior rectus muscle which contains more type I and the masseter and iliopsoas muscles with more type IIb muscle fibers. IHC indicated presence of trigeminal, catecholaminergic and cholinergic nerve endings. 3D reconstructions supported the SEM data. Endonasal video analysis of patients after DCR with a nasally open lacrimal sac revealed bulging of the temporal wall of the lacrimal sac during blinking. On the basis of these findings, a modified lacrimal pump theory is proposed.
CONCLUSION: The results support the hypothesis that contraction of Horner-Duverney's muscle leads to closure of the canaliculi in their first two thirds based on the special arrangement of muscle fibers and connective tissue fibers. This causes the tear fluid in the canaliculi to be pressed/transported towards the lacrimal sac. The medial third of the vertical portions of the canaliculi, the canaliculus communis and the intrasaccal portion of the canaliculus are compressed by the shortening and thickening of the Horner-Duverney muscle from dorsal, which leads to a compression of the canaliculi lumens in this part of the system, thereby pushing the lacrimal fluid further towards the lacrimal sac. The mix of fast contracting and fatigue resistant muscle fibers is ideally suited for the blink mechanism that is complexly regulated by the nervous system.
Copyright © 2020 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Canaliculus; Efferent tear ducts; Horner's muscle; Lacrimal pump; Nasolacrimal ducts; Orbicularis oculi; Tear drainage; Tear flow

Mesh:

Year:  2020        PMID: 32730907     DOI: 10.1016/j.jtos.2020.07.013

Source DB:  PubMed          Journal:  Ocul Surf        ISSN: 1542-0124            Impact factor:   5.033


  3 in total

Review 1.  The Communication between Ocular Surface and Nasal Epithelia in 3D Cell Culture Technology for Translational Research: A Narrative Review.

Authors:  Malik Aydin; Jana Dietrich; Joana Witt; Maximiliane S C Finkbeiner; Jonas J-H Park; Stefan Wirth; Christine E Engeland; Friedrich Paulsen; Anja Ehrhardt
Journal:  Int J Mol Sci       Date:  2021-11-30       Impact factor: 5.923

2.  Holding back the tears: does marsupialisation of a remnant canaliculus after tumour resection help eliminate epiphora?

Authors:  Mohammad Javed Ali; Raman Malhotra; Geoffrey E Rose; Bhupendra C K Patel
Journal:  BMJ Open Ophthalmol       Date:  2022-08

3.  Commentary: The electromyographic analysis of orbicularis oculi muscle in epiphora.

Authors:  Mohammad Javed Ali
Journal:  Indian J Ophthalmol       Date:  2022-06       Impact factor: 2.969

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.