One-step modification of nano-polyaniline/glucose oxidase on double-side printed flexible electrode for continuous glucose monitoring: Characterization, cytotoxicity evaluation and in vivo experiment.

Yu Cai1, Bo Liang2, Shidie Chen1, Qin Zhu1, Tingting Tu1, Ke Wu3, Qingpeng Cao1, Lu Fang4, Xiao Liang3, Xuesong Ye5.   

Abstract

The single-step modification of the nanostructured polyaniline (PANI)/glucose oxidase (GOD) enzyme on double-sided, screen-printed, flexible electrodes doped with Prussian blue (PB), has been achieved and successfully applied in continuous glucose monitoring in vivo, and its biocompatibility has been evaluated systematically. The proposed fabrication procedure is simple, low cost, and suitable for large-scale production. PB doped with carbon ink catalyzes the reduction of hydrogen peroxide (H2O2) in low-voltage conditions, which could help eliminate interferences. And the PANI/GOD nanostructure makes the GOD enzyme more stable for long-term, in vivo monitoring. More importantly, a polyurethane (PU) layer is deposited on the electrode's surface as a diffusion limiting membrane that enhanced the linear range and biocompatibility. In tests in vitro, the proposed biosensor achieved a linear range of 0-12 mM and a good sensitivity of 16.66 μA·mM-1·cm-2(correlation coefficient R2 = 0.9962) with an excellent specificity to glucose. The biosensor exhibits long-term stability, with a maximum lifespan of 14 days when stored in phosphate buffer solution at 4 °C, and achieves a sensitivity of 120%. The biocompatibilities of the electrode materials have also been systematically evaluated in cytotoxicity and cell adhesion tests to ensure the safety of implantation. In experiments in vivo, the biosensor can successfully monitor the glucose level fluctuation of rats after 24 h following implantation. Overall, the biosensor fabricated with the double-side, screen-printing process, satisfies the glucose monitoring range in vivo and eliminates various types of interference, thus establishing a new, large-scale production procedure for flexible in vivo biosensors.
Copyright © 2020 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Cytotoxicity; Glucose biosensor; Implantable sensor; Polyaniline; Prussian blue; Screen-printed electrode

Mesh:

Substances:

Year:  2020        PMID: 32729528     DOI: 10.1016/j.bios.2020.112408

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  5 in total

Review 1.  Unlocking All-Solid Ion Selective Electrodes: Prospects in Crop Detection.

Authors:  Jiawei Zhai; Bin Luo; Aixue Li; Hongtu Dong; Xiaotong Jin; Xiaodong Wang
Journal:  Sensors (Basel)       Date:  2022-07-25       Impact factor: 3.847

2.  Continuous Glucose Monitoring System Based on Percutaneous Microneedle Array.

Authors:  Ming-Nan Chien; Yu-Jen Chen; Chin-Han Bai; Jung-Tung Huang
Journal:  Micromachines (Basel)       Date:  2022-03-20       Impact factor: 2.891

3.  Magnetic Immunosensor Coupled to Enzymatic Signal for Determination of Genomic DNA Methylation.

Authors:  Yitao Liang; Bin Zhang; Zexin Xue; Xuesong Ye; Bo Liang
Journal:  Biosensors (Basel)       Date:  2022-03-04

Review 4.  Progress of Polyaniline Glucose Sensors for Diabetes Mellitus Management Utilizing Enzymatic and Non-Enzymatic Detection.

Authors:  Velia Osuna; Alejandro Vega-Rios; Erasto Armando Zaragoza-Contreras; Iván Alziri Estrada-Moreno; Rocio B Dominguez
Journal:  Biosensors (Basel)       Date:  2022-02-22

5.  A Dual Electrode Biosensor for Glucose and Lactate Measurement in Normal and Prolonged Obese Mice Using Single Drop of Whole Blood.

Authors:  Mukesh Thapa; Ryong Sung; Yun Seok Heo
Journal:  Biosensors (Basel)       Date:  2021-12-09
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.