Mechanical performance and implications on bone healing of different screw configurations for plate fixation of diaphyseal tibia fractures: a computational study.

Francesco Travascio1,2,3, Leonard T Buller4, Edward Milne5, Loren Latta6,5.   

Abstract

Diaphyseal tibia fractures may require plate fixation for proper healing to occur. Currently, there is no consensus on the number of screws required for proper fixation or the optimal placement of the screws within the plate. Mechanical stability of the construct is a leading criterion for choosing plate and screws configuration. However, number and location of screws have implications on the mechanical environment at the fracture site and, consequently, on bone healing response: The interfragmentary motion attained with a specific plate and screw construct may elicit mechano-transduction signals influencing cell-type differentiation, which in turn affects how well the fracture heals. This study investigated how different screw configurations affect mechanical performance of a tibia plate fixation construct. Three configurations of an eight-hole plate were considered with the fracture in the center of the plate: eight screws-screws at first, fourth, fifth and eighth hole and screws at first, third, sixth and eighth hole. Constructs' stiffness was compared through biomechanical tests on bone surrogates. A finite element model of tibia diaphyseal fracture was used to conduct a stress analysis on the implanted hardware. Finally, the potential for bone regeneration of each screw configuration was assessed via the computational model through the evaluation of the magnitude of mechano-transduction signals at the bone callus. The results of this study indicate that having screws at fourth and fifth holes represents a preferable configuration since it provides mechanical properties similar to those attained by the stiffest construct (eight screws), and elicits an ideal bone regenerative response.

Entities:  

Keywords:  Biphasic; Bone repair; Finite element analysis; Mechanical stimuli index; Mechano-transduction

Mesh:

Year:  2020        PMID: 32725431     DOI: 10.1007/s00590-020-02749-5

Source DB:  PubMed          Journal:  Eur J Orthop Surg Traumatol        ISSN: 1633-8065


  4 in total

1.  [Combined Kuntscher nailing and screw fixation (author's transl)].

Authors:  I Kempf; A Grosse; D Lafforgue
Journal:  Rev Chir Orthop Reparatrice Appar Mot       Date:  1978-12

2.  Assessment of a mechano-regulation theory of skeletal tissue differentiation in an in vivo model of mechanically induced cartilage formation.

Authors:  Lauren Nicole Miller Hayward; Elise F Morgan
Journal:  Biomech Model Mechanobiol       Date:  2009-01-21

3.  Mechanical stimulation alters tissue differentiation and molecular expression during bone healing.

Authors:  Kristy T Salisbury Palomares; Ryan E Gleason; Zachary D Mason; Dennis M Cullinane; Thomas A Einhorn; Louis C Gerstenfeld; Elise F Morgan
Journal:  J Orthop Res       Date:  2009-09       Impact factor: 3.494

Review 4.  Mechanotransduction in musculoskeletal tissue regeneration: effects of fluid flow, loading, and cellular-molecular pathways.

Authors:  Yi-Xian Qin; Minyi Hu
Journal:  Biomed Res Int       Date:  2014-08-18       Impact factor: 3.411

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.