Literature DB >> 32722987

Endovascular treatment of complex middle cerebral artery aneurysms using TuBridge flow diverters.

Feng Liang1, Yibing Yang1, Lijuan Luo1, Bingye Liao2, Guofeng Zhang1, Siqi Ou1, Weiping Xiao1, Ning Guo1, Tiewei Qi1.   

Abstract

BACKGROUND: The safety and efficacy of the TuBridge flow diverter in treating middle cerebral artery aneurysms remains unknown. In this study, we report our preliminary experience treating complex middle cerebral artery aneurysms using the TuBridge flow diverter.
METHODS: A prospectively maintained database of intracranial aneurysms treated with the TuBridge flow diverter was retrospectively reviewed, and patients with middle cerebral artery aneurysms were included in this study. Demographics, aneurysm features, complications, and clinical and angiographic outcomes were assessed. Evaluation of the angiographic results included occlusion grade of aneurysm (O'Kelly-Marotta grading scale), patency of jailed branch(es), and in-stent stenosis.
RESULTS: Eight patients with eight middle cerebral artery aneurysms were included in this study. The mean aneurysm size was 11.8 ± 6.8 mm. There were no procedure-related complications and there was no morbidity or mortality at a mean follow-up of 11.3 ± 3.6 months. All patients had follow-up angiograms at a mean of 7.5 ± 4.0 months after surgery. Of the eight patients, there was 1 (12.5%) O'Kelly-Marotta grading scale A, 3 (37.5%) O'Kelly-Marotta grading scale B, 1 (12.5%) O'Kelly-Marotta grading scale C, and 3 (37.5%) O'Kelly-Marotta grading scale D. Of the seven patients with jailed branch, the blood flow of jailed branch was unchanged in 4 (57.1%), decreased in 2 (28.6%), and occluded in 1 (14.3%). In-stent stenosis was mild in 2 (25%) patients and moderate in 1 (12.5%) patient.
CONCLUSION: Midterm results suggest that endovascular treatment of middle cerebral artery aneurysms using the TuBridge flow diverter is safe and associated with good outcomes. The TuBridge flow diverter may be an option for complex middle cerebral artery aneurysms that are difficult to treat with either clipping or coiling.

Entities:  

Keywords:  TuBridge flow diverter; endovascular treatment; middle cerebral artery aneurysm

Mesh:

Substances:

Year:  2020        PMID: 32722987      PMCID: PMC7645195          DOI: 10.1177/1591019920946216

Source DB:  PubMed          Journal:  Interv Neuroradiol        ISSN: 1591-0199            Impact factor:   1.610


  29 in total

1.  Variable porosity of the pipeline embolization device in straight and curved vessels: a guide for optimal deployment strategy.

Authors:  M Shapiro; E Raz; T Becske; P K Nelson
Journal:  AJNR Am J Neuroradiol       Date:  2013-09-26       Impact factor: 3.825

2.  Long-Term Clinical and Angiographic Outcomes Following Pipeline Embolization Device Treatment of Complex Internal Carotid Artery Aneurysms: Five-Year Results of the Pipeline for Uncoilable or Failed Aneurysms Trial.

Authors:  Tibor Becske; Waleed Brinjikji; Matthew B Potts; David F Kallmes; Maksim Shapiro; Christopher J Moran; Elad I Levy; Cameron G McDougall; István Szikora; Giuseppe Lanzino; Henry H Woo; Demetrius K Lopes; Adnan H Siddiqui; Felipe C Albuquerque; David J Fiorella; Isil Saatci; Saruhan H Cekirge; Aaron L Berez; Daniel J Cher; Zsolt Berentei; Miklós Marosfoi; Peter K Nelson
Journal:  Neurosurgery       Date:  2017-01-01       Impact factor: 4.654

3.  Endovascular treatment of middle cerebral artery aneurysms with flow modification with the use of the pipeline embolization device.

Authors:  K Yavuz; S Geyik; I Saatci; H S Cekirge
Journal:  AJNR Am J Neuroradiol       Date:  2013-09-26       Impact factor: 3.825

4.  Transient in-stent stenosis: a common finding after flow diverter implantation.

Authors:  Ruben Mühl-Benninghaus; Alena Haußmann; Andreas Simgen; Toshiki Tomori; Wolfgang Reith; Umut Yilmaz
Journal:  J Neurointerv Surg       Date:  2018-07-03       Impact factor: 5.836

5.  The Fate of Side Branches Covered by Flow Diverters-Results from 140 Patients.

Authors:  Pervinder Bhogal; Oliver Ganslandt; Hansjörg Bäzner; Hans Henkes; Marta Aguilar Pérez
Journal:  World Neurosurg       Date:  2017-04-21       Impact factor: 2.104

6.  A novel flow-diverting device (Tubridge) for the treatment of 28 large or giant intracranial aneurysms: a single-center experience.

Authors:  Y Zhou; P-F Yang; Y-B Fang; Y Xu; B Hong; W-Y Zhao; Q Li; R Zhao; Q-H Huang; J-M Liu
Journal:  AJNR Am J Neuroradiol       Date:  2014-04-10       Impact factor: 3.825

7.  Patency of anterior circulation branch vessels after Pipeline embolization: longer-term results from 82 aneurysm cases.

Authors:  Leonardo Rangel-Castilla; Stephan A Munich; Naser Jaleel; Marshall C Cress; Chandan Krishna; Ashish Sonig; Kenneth V Snyder; Adnan H Siddiqui; Elad I Levy
Journal:  J Neurosurg       Date:  2016-06-10       Impact factor: 5.115

Review 8.  Treatment of Middle Cerebral Artery Aneurysms with Flow-Diverter Stents: A Systematic Review and Meta-Analysis.

Authors:  F Cagnazzo; D Mantilla; P-H Lefevre; C Dargazanli; G Gascou; V Costalat
Journal:  AJNR Am J Neuroradiol       Date:  2017-10-05       Impact factor: 3.825

9.  Flow Diversion for the Treatment of MCA Bifurcation Aneurysms-A Single Centre Experience.

Authors:  Pervinder Bhogal; Muhammad AlMatter; Hansjörg Bäzner; Oliver Ganslandt; Hans Henkes; Marta Aguilar Pérez
Journal:  Front Neurol       Date:  2017-02-02       Impact factor: 4.003

10.  Flow diversion beyond the circle of Willis: endovascular aneurysm treatment in peripheral cerebral arteries employing a novel low-profile flow diverting stent.

Authors:  Karl-Titus Hoffmann; Jürgen Meixensberger; Ulf Quäschling; Stefan Schob; Cindy Richter; Pervinder Bhogal; Katharina Köhlert; Uwe Planitzer; Svitlana Ziganshyna; Dirk Lindner; Cordula Scherlach; Ulf Nestler
Journal:  J Neurointerv Surg       Date:  2019-05-14       Impact factor: 5.836

View more
  2 in total

1.  Use of flow diverter device in basilar artery for aneurysm treatment: Case series and literature review.

Authors:  Chuanchuan Wang; Deyuan Zhu; Xiaolong Xu; Yu Zhou; Rui Zhao; Qiang Li; Pengfei Yang; Qinghai Huang; Yi Xu; Jianmin Liu; Yibin Fang
Journal:  Front Neurol       Date:  2022-08-17       Impact factor: 4.086

2.  Flow diversion effect of the leo braided stent for aneurysms in the posterior and distal anterior circulations: A multicenter cohort study.

Authors:  Yu Duan; Binbin Xu; Xuanfeng Qin; Renling Mao; Yuanyuan Hu; Bin Zhou; Jian Li; Gong Chen
Journal:  Front Neurol       Date:  2022-09-27       Impact factor: 4.086

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.