Literature DB >> 32721930

Liver-ultrasound based motion modelling to estimate 4D dose distributions for lung tumours in scanned proton therapy.

Alina Giger1,2,3, Miriam Krieger4,5,3, Christoph Jud1,2, Alisha Duetschler4,5, Rares Salomir6,7, Oliver Bieri1,8, Grzegorz Bauman1,8, Damien Nguyen1,8, Damien C Weber4,9,10, Antony J Lomax4,5, Ye Zhang4, Philippe C Cattin1,2.   

Abstract

Motion mitigation strategies are crucial for scanned particle therapy of mobile tumours in order to prevent geometrical target miss and interplay effects. We developed a patient-specific respiratory motion model based on simultaneously acquired time-resolved volumetric MRI and 2D abdominal ultrasound images. We present its effects on 4D pencil beam scanned treatment planning and simulated dose distributions. Given an ultrasound image of the liver and the diaphragm, principal component analysis and Gaussian process regression were applied to infer dense motion information of the lungs. 4D dose calculations for scanned proton therapy were performed using the estimated and the corresponding ground truth respiratory motion; the differences were compared by dose difference volume metrics. We performed this simulation study on 10 combined CT and 4DMRI data sets where the motion characteristics were extracted from 5 healthy volunteers and fused with the anatomical CT data of two lung cancer patients. Median geometrical estimation errors below 2 mm for all data sets and maximum dose differences of [Formula: see text] = 43.2% and [Formula: see text] = 16.3% were found. Moreover, it was shown that abdominal ultrasound imaging allows to monitor organ drift. This study demonstrated the feasibility of the proposed ultrasound-based motion modelling approach for its application in scanned proton therapy of lung tumours.

Entities:  

Mesh:

Year:  2020        PMID: 32721930     DOI: 10.1088/1361-6560/abaa26

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  2 in total

1.  The potential of Gantry beamline large momentum acceptance for real time tumour tracking in pencil beam scanning proton therapy.

Authors:  Giovanni Fattori; Ye Zhang; David Meer; Damien Charles Weber; Antony John Lomax; Sairos Safai
Journal:  Sci Rep       Date:  2020-09-18       Impact factor: 4.379

2.  Synthetic 4DCT(MRI) lung phantom generation for 4D radiotherapy and image guidance investigations.

Authors:  Alisha Duetschler; Grzegorz Bauman; Oliver Bieri; Philippe C Cattin; Stefanie Ehrbar; Georg Engin-Deniz; Alina Giger; Mirjana Josipovic; Christoph Jud; Miriam Krieger; Damien Nguyen; Gitte F Persson; Rares Salomir; Damien C Weber; Antony J Lomax; Ye Zhang
Journal:  Med Phys       Date:  2022-03-17       Impact factor: 4.506

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.