Literature DB >> 32718722

Utility of Three-Dimensional Transesophageal Echocardiography for Mitral Annular Sizing in Transcatheter Mitral Valve Replacement Procedures: A Cardiac Computed Tomographic Comparative Study.

Augustin Coisne1, François Pontana2, Samy Aghezzaf3, Stéphanie Mouton3, Hélène Ridon3, Marjorie Richardson3, Anne-Sophie Polge3, Benjamin Longère4, Valentina Silvestri4, Julien Pagniez4, Antoine Bical5, Natacha Rousse5, Pavel Overtchouk5, Juan F Granada6, Rebecca T Hahn7, Thomas Modine5, David Montaigne8.   

Abstract

BACKGROUND: Three-dimensional (3D) transesophageal echocardiographic (TEE) imaging is frequently used as an initial screening tool in the evaluation of patients who are candidates for transcatheter mitral valve replacement (TMVR). However, little is known about the imaging correlation with the gold standard, computed tomographic (CT) imaging. The aims of this study were to test the quantitative differences between these two modalities and to determine the best 3D TEE parameters for TMVR screening.
METHODS: Fifty-seven patients referred to the heart valve clinic for TMVR with prostheses specifically designed for the mitral valve were included. Mitral annular (MA) analyses were performed using commercially available software on 3D TEE and CT imaging.
RESULTS: Three-dimensional TEE imaging was feasible in 52 patients (91%). Although 3D TEE measurements were slightly lower than those obtained on CT imaging, measurements of both projected MA area and perimeter showed excellent correlations, with small differences between the two modalities (r = 0.88 and r = 0.92, respectively, P < .0001). Correlations were significant but lower for MA diameters (r = 0.68-0.72, P < .0001) and mitroaortic angle (r = 0.53, P = .0001). Receiver operating characteristic curve analyses showed that 3D TEE imaging had a good ability to predict TMVR screening success, defined by constructors on the basis of CT measurements, with ranges of 12.9 to 15 cm2 for MA area (area under the curve [AUC] = 0.88-0.91, P < .0001), 128 to 139 mm for MA perimeter (AUC = 0.85-0.91, P < .0001), 35 to 39 mm for anteroposterior diameter (AUC = 0.79-0.84, P < .0001), and 37 to 42 mm for posteromedial-anterolateral diameter (AUC = 0.81-0.89, P < .0001).
CONCLUSIONS: Three-dimensional TEE measurements of MA dimensions display strong correlations with CT measurements in patients undergoing TMVR screening. Three-dimensional TEE imaging should be proposed as a reasonable alternative to CT imaging in this vulnerable population.
Copyright © 2020 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Heart team; Mitral annulus; Multimodality imaging; Three-dimensional; Transcatheter mitral valve replacement

Year:  2020        PMID: 32718722     DOI: 10.1016/j.echo.2020.04.030

Source DB:  PubMed          Journal:  J Am Soc Echocardiogr        ISSN: 0894-7317            Impact factor:   5.251


  1 in total

1.  Open-Source Tool Kit for Interactive Planning of Transcatheter Mitral Valve Replacement Using Multimodality Imaging.

Authors:  Christian Herz; Alana Cianciulli; Stephen Ching; Chad Vigil; Andras Lasso; Hannah H Nam; Simon Drouin; David M Biko; Matthew Gillespie; Gabor Fichtinger; Matthew A Jolley
Journal:  J Am Soc Echocardiogr       Date:  2021-04-02       Impact factor: 7.722

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.