Literature DB >> 32710720

Comparison of image quality in brain MRI with and without MR compatible incubator and predictive value of brain MRI at expected delivery date in preterm babies.

Franziska Müller1, Hans Proquitté2, Karl-Heinz Herrmann3, Thomas Lehmann4, Hans-Joachim Mentzel1.   

Abstract

Objectives MR compatible incubators (MRcI) offer the examination of preterm and critically ill infants in controlled environment. The aim of the study was to compare objective and subjective image quality as well as diagnostic value of MRI brain examinations with and without using the MRcI. Thus, predictive value of brain MRI at expected delivery date in general was investigated. Methods This retrospective study included MRI brain examinations conducted at patients' corrected age ≤6 months and presence of four standard sequences (PD TSE transversal, T2 TSE transversal, T2 TSE sagittal and T1 SE transversal). Signal-to-Noise Ratio (SNR) and Contrast-to-Noise Ratio (CNR) was calculated. Subjective image quality was estimated using a 5-point Likert scale. Findings of MRI were compared with those of previous transfontanellar ultrasound because of additional diagnostic information. Severe brain abnormality scaled by score of Kidokoro was related to results of Munich Functional Developmental Diagnostics (MFDD) within first year. Results One hundred MRI brain examinations (76 with MRcI, 24 without MRcI) were performed in 79 patients. Using the MRcI SNR and CNR were significantly higher in PD- and in T2-weighted sequences (p<0.05). TSE PD transversal demonstrated a higher risk of non-diagnostic quality using MRcI (OR 5.23; 95%-CI 1.86-14.72). MRcI revealed additional diagnostic information (OR 5.69; 95%-CI 1.15-28.24). Severe brain abnormality was associated with walking deficits (r=0.570; p=0.021). Conclusions The MRcI increased objective image quality and revealed additional diagnostic information to transfontanellar ultrasound. Nevertheless, prediction of infants' future development remains limited.

Entities:  

Keywords:  MR compatible incubator; image quality; neurodevelopmental diagnostic; predictive value

Mesh:

Year:  2020        PMID: 32710720     DOI: 10.1515/jpm-2020-0051

Source DB:  PubMed          Journal:  J Perinat Med        ISSN: 0300-5577            Impact factor:   1.901


  1 in total

1.  [Application of magnetic resonance imaging-compatible incubator in cranial magnetic resonance imaging for neonates: a multicenter prospective randomized clinical trial].

Authors:  Lian Liu; Peng Zhang; Hong-Ping Xia; Bin Wang; Xue-Ling Ma; Guo-Qiang Cheng; Yuan Shi
Journal:  Zhongguo Dang Dai Er Ke Za Zhi       Date:  2020-12
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.