Helle D Zacho1,2, Ramune Aleksyniene1, June A Ejlersen3, Joan Fledelius3, Lars J Petersen1,2. 1. Department of Nuclear Medicine and Clinical Cancer Research Center, Aalborg University Hospital. 2. Department of Clinical Medicine, Aalborg University, Aalborg. 3. Department of Nuclear Medicine, Regional Hospital West Jutland, Herning, Denmark.
Abstract
OBJECTIVE: To investigate inter- and intraobserver agreement using standard (std)-single-photon emission computed tomography/computed tomography (SPECT/CT) or ultra-fast acquisition (UF)-SPECT/CT as an add-on to planar whole-body bone scintigraphy (WB-BS) for the detection of bone metastases in patients with known cancer. METHODS: Images from patients (n = 104) participating in a prospective trial comparing SPECT/CT as an add-on to WB-BS with two different acquisition methods (std-SPECT/CT; 20 s per view, 32 views and UF-SPECT/CT; 16 views of 10 s per view) were included. The combinations of WB-BS with the two different SPECT/CT acquisition methods were independently evaluated by two experienced observers using a three-point scale (M0: no metastases, Me: equivocal for bone metastases and M1: bone metastases). The observers re-evaluated the scans 6 months later. Inter- and intraobserver agreement was calculated using linear weighted kappa. RESULTS: The linear weighted kappa for the interobserver agreement was 0.78 [95% confidence interval (CI) 0.61-0.94] for WB-BS with std-SPECT/CT and 0.84 (95% CI 0.67-1.00) for WB-BS with UF-SPECT/CT. Similar values were observed for the intraobserver agreement, in which the linear weighted kappa was 0.76 (95% CI 0.60-0.92) and 0.73 (95% CI 0.57-0.90) for std-SPECT/CT and UF-SPECT/CT, respectively. CONCLUSION: Satisfactory inter- and intraobserver agreement was seen for both acquisition methods, emphasizing that the use of SPECT/CT as an add-on to WB-BS is a robust method for the detection of bone metastases even when conducted with a very short acquisition time.
OBJECTIVE: To investigate inter- and intraobserver agreement using standard (std)-single-photon emission computed tomography/computed tomography (SPECT/CT) or ultra-fast acquisition (UF)-SPECT/CT as an add-on to planar whole-body bone scintigraphy (WB-BS) for the detection of bone metastases in patients with known cancer. METHODS: Images from patients (n = 104) participating in a prospective trial comparing SPECT/CT as an add-on to WB-BS with two different acquisition methods (std-SPECT/CT; 20 s per view, 32 views and UF-SPECT/CT; 16 views of 10 s per view) were included. The combinations of WB-BS with the two different SPECT/CT acquisition methods were independently evaluated by two experienced observers using a three-point scale (M0: no metastases, Me: equivocal for bone metastases and M1: bone metastases). The observers re-evaluated the scans 6 months later. Inter- and intraobserver agreement was calculated using linear weighted kappa. RESULTS: The linear weighted kappa for the interobserver agreement was 0.78 [95% confidence interval (CI) 0.61-0.94] for WB-BS with std-SPECT/CT and 0.84 (95% CI 0.67-1.00) for WB-BS with UF-SPECT/CT. Similar values were observed for the intraobserver agreement, in which the linear weighted kappa was 0.76 (95% CI 0.60-0.92) and 0.73 (95% CI 0.57-0.90) for std-SPECT/CT and UF-SPECT/CT, respectively. CONCLUSION: Satisfactory inter- and intraobserver agreement was seen for both acquisition methods, emphasizing that the use of SPECT/CT as an add-on to WB-BS is a robust method for the detection of bone metastases even when conducted with a very short acquisition time.