| Literature DB >> 32690548 |
Baldeep Singh Sidhu1,2, Tiago Rua3,2, Justin Gould3,2, Bradley Porter3,2, Benjamin Sieniewicz3,2, Steven Niederer3, Christopher Aldo Rinaldi3,2, Gerald Carr-White3,2.
Abstract
INTRODUCTION: Patient evaluation before cardiac resynchronisation therapy (CRT) remains heterogeneous across centres and it is suspected a proportion of patients with unfavourable characteristics proceed to implantation. We developed a unique CRT preassessment clinic (CRT PAC) to act as a final review for patients already considered for CRT. We hypothesised that this clinic would identify some patients unsuitable for CRT through updated investigations and review. The purpose of this analysis was to determine whether the CRT PAC led to savings for the National Health Service (NHS).Entities:
Keywords: cardiac resynchronisation therapy; delivery of care; pacemakers
Mesh:
Year: 2020 PMID: 32690548 PMCID: PMC7373313 DOI: 10.1136/openhrt-2020-001249
Source DB: PubMed Journal: Open Heart ISSN: 2053-3624
Unit cost estimates
| Type of National Health Service event | Estimated mean cost (in £) | |
| Clinic | No specialised clinic | 0 |
| Cardiac resynchronisation therapy preassessment clinic | 561 | |
| Cardiac resynchronisation therapy procedure | Cardiac resynchronisation therapy defibrillator | 27 413 |
| Cardiac resynchronisation therapy pacemaker | 10 542 | |
| No CRT implantation | 0 | |
| Follow-up costs | Hospital admissions due to heart failure events | 7130 |
The mean unit cost for the cardiac resynchronisation therapy (CRT) preassessment clinic (£561) was estimated based on the utilisation of: (i) new outpatient appointment for cardiology (244/244 participants with an estimated unit cost of £200 per new outpatient consultant appointment); (ii) cardiac magnetic resonance (CMR) imaging (125/244 participants, unit cost of £544 based on unbundled CMR tariff) and (iii) echocardiogram (244/244 participants, unit cost of £82 for unbundled echocardiography). The mean unit costs for the cardiac resynchronisation therapy implantation procedures were the sum of the cost of the device, cost for the cardiac catheter laboratory staff and average hospital admission length. This amount was estimated by averaging the cost of five patients who underwent each intervention at our institution. The mean unit cost of hospital admissions during the follow-up period of 1 year was based on the costs incurred in the ‘specialised clinic’ group.
Baseline patient demographics
| Variable | Overall (n=244) | Eligible for CRT (n=184) | Ineligible for CRT (n=60) | P value |
| Characteristics | ||||
| Age, ±SD | 70.6±10.8 | 70.8±10.6 | 69.8±11.5 | 0.576 |
| Female, N (%) | 68 (27.9) | 44 (23.9) | 24 (40.0) | 0.016 |
| Ischaemic aetiology, N (%) | 124 (50.8) | 97 (52.7) | 27 (45.0) | 0.299 |
| Comorbidities, N (%) | ||||
| Hypertension | 87 (35.7) | 69 (37.50) | 18 (30.0) | 0.292 |
| Diabetes mellitus | 70 (28.7) | 58 (31.5) | 12 (20.0) | 0.087 |
| Chronic kidney disease | 60 (23.8) | 43 (23.4) | 17 (28.3) | 0.438 |
| New York Heart Association Functional class, ±SD | 2.5±0.7 | 2.6±0.7 | 2.4±0.7 | 0.033 |
| QRS duration, ±SD | 156.7±28.2 | 161.5±26.7 | 142.0±27.8 | <0.001 |
| Left bundle branch block, N (%) | 137 (56.1) | 109 (59.2) | 28 (46.7) | 0.088 |
| Echocardiography, ±SD | ||||
| Left ventricular ejection fraction | 31.9±10.2 | 29.1±8.2 | 40.5±11.2 | <0.001 |
| Left ventricular end-diastolic volume | 188.8±78.7 | 203.7±80.5 | 140.8±48.0 | <0.001 |
| Left ventricular end-systolic volume | 129.7±55.8 | 143.3±53.7 | 85.8±53.7 | <0.001 |
CRT, cardiac resynchronisation therapy; N, number.
Figure 1Decision tree associated with the management of patients requiring cardiac resynchronisation therapy with and without a preassessment clinic This decision tree model was used to estimate the cost of the cardiac resynchronisation therapy preassessment clinic (CRT PAC). The specialised clinic refers to the CRT PAC. Patients requiring CRT with no specialised clinic were considered to either proceed to CRT implantation or not. Similarly, patients attending the specialised clinic had the same options but as a result of the CRT PAC review, 60 patients were unsuitable to proceed directly to CRT. During the follow-up period, 12 patients underwent device implantation but 48 patients did not. CRT, cardiac resynchronisation therapy, HF, heart failure.
Total costs and mean cost per patient associated with both clinical strategies
| Strategy | Total cost for the National Health Service | Total mean cost per patient |
| No CRT PAC | £5 288 257 | £21 673 |
| CRT PAC | £4 231 955 | £17 344 |
| Potential cost-savings | £1 056 302 | £4329 |
CRT PAC, cardiac resynchronisation therapy preassessment clinic.