Literature DB >> 32681177

Safety and efficacy of transvenous mechanical lead extraction in patients with abandoned leads.

Luca Segreti1, Mario Giannotti Santoro1, Andrea Di Cori1, Federico Fiorentini1, Giulio Zucchelli1, Giulia Bernini1, Raffaele De Lucia1, Stefano Viani1, Luca Paperini1, Valentina Barletta1, Ezio Soldati1, Maria Grazia Bongiorni1.   

Abstract

AIMS: Optimal management of redundant or malfunctioning leads is controversial. We aimed to assess safety and efficacy of mechanical transvenous lead extraction (TLE) in patients with abandoned leads. METHODS AND
RESULTS: Consecutive TLE procedures performed in our centre from January 2009 to December 2017 were considered. We evaluated the safety and efficacy of mechanical TLE in patients with abandoned (Group 1) compared to non-abandoned (Group 2) leads. We analysed 1210 consecutive patients that required transvenous removal of 2343 leads. Group 1 accounted for 250 patients (21%) with a total of 617 abandoned leads (26%). Group 2 comprised 960 patients (79%) with 1726 leads (74%). The total number of leads (3.0 vs. 2.0), dwelling time of the oldest lead (108.00 months vs. 60.00 months) and infectious indications for TLE were higher in Group 1. Clinical success was achieved in 1168 patients (96.5%) with a lower rate in Group 1 (90.4% vs. 98.1%; P < 0.001). Major complications occurred in only 9 patients (0.7%), without significant differences among the two groups. The presence of one or more abandoned leads [odds ratio (OR) 3.47; 95% confidence interval (CI) 1.07-11.19; P = 0.037] and dwelling time of the oldest lead (OR 1.01 for a month; 95% CI 1.01-1.02; P < 0.001) were associated with a higher risk of clinical failure.
CONCLUSION: Transvenous mechanical lead extraction is a safe procedure also in high-risk settings, as patients with abandoned leads. Success rate resulted a bit lower, especially in the presence of abandoned leads with long implantation time. Published on behalf of the European Society of Cardiology. All rights reserved.
© The Author(s) 2020. For permissions, please email: journals.permissions@oup.com.

Entities:  

Keywords:  Abandoned leads; Implantable cardioverter-defibrillator; Lead extraction; Pacemaker; Safety

Mesh:

Year:  2020        PMID: 32681177     DOI: 10.1093/europace/euaa134

Source DB:  PubMed          Journal:  Europace        ISSN: 1099-5129            Impact factor:   5.214


  2 in total

1.  Reducing CIED-Related Morbidity: "LESS Is More".

Authors:  François D Regoli
Journal:  J Clin Med       Date:  2022-08-16       Impact factor: 4.964

2.  Transvenous Lead Extraction without Procedure-Related Deaths in 1000 Consecutive Patients: A Single-Center Experience.

Authors:  Paweł Stefańczyk; Dorota Nowosielecka; Łukasz Tułecki; Konrad Tomków; Anna Polewczyk; Wojciech Jacheć; Andrzej Kleinrok; Wojciech Borzęcki; Andrzej Kutarski
Journal:  Vasc Health Risk Manag       Date:  2021-08-05
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.